Troubleshooting; Module Does Not Move; End Position Signal Not Present; Linear Module Proposes At The End Positions - SCHUNK KLM Series Assembly And Operating Manual

Linear module
Table of Contents

Advertisement

7 Troubleshooting

7.1 Module does not move?

Possible cause
Compressed air is missing
Pneumatically connected incorrectly

7.2 End position signal not present

Possible cause
Initiator to stop inaccurately adjusted
Defective initiator
Cable breakage.

7.3 Linear module proposes at the end positions

Possible cause
Damping wrong adjustet.
Shock absorber defective.
Stroke speed too high.

7.4 Payload swings in the final position

Possible cause
Stroke speed too high.
Bad damping.
Unfavorable installation.
Unfavorable CLM - Type.
03.00 | KLM | Assembly and operating manual | en | 389173
Corrective action
Check air compression
Check the air supply
Corrective action
Readjust the initiator
Exchange the initiator
Replace the initiation cable
Corrective action
Adjust stop screw.
Change the shock absorber.
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
Corrective action
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
Adjust damping (stop
screw).Final positions
Check construction.
Use larger LM - Type.
Troubleshooting
[
 24]
}
29

Advertisement

Table of Contents
loading

Table of Contents