6.3 Dust cover
6.4 Rod lock
03.00 | KLM | Assembly and operating manual | en | 389173
CAUTION
Observe general notes at
1. Remove the mounting screw for the piston rod.
2. Loosen the mounting screws for the end plates and remove the
end plates.
3. SPlace the dust cover on the guide shafts and mount on the top
plates.
4. Place end plates on the guide shafts and tighten with fastening
screws; mount fastening elements for the piston rod.
WARNING
The rod lock is not a safety component for personal protection
in the sense of the Machine Directive.
CAUTION
Damage to the rod lock due to incorrect actuation / overload!
The rod lock may only be triggered and unlocked when the
•
product has been shut down.
See the data on static holding force in the catalog. The forces
•
occurring in a clamped condition must not exceed the holding
force.
In the event of a dynamic load or overload (e.g. drop in
•
pressure during movement), the clamping cartridge must be
checked and replaced if necessary.
Handling
[
24]
}
Handling
27