Assembly
4 Assembly
4.1 Design precautions
4.2 Notes of Installation
16
03.00 | KLM | Assembly and operating manual | en | 389173
• A protective cover is recommended to minimize the risk of
injury.
• Ensure that loose, solid and / or attached parts are tightened.
• Due to the high levels of kinetic energy, shock absorbers must
be used
• Take into account possible that the operating pressure can drop
due to power outages.
• Pay attention to the possibility of the failure of power supplies.
• Mount the compressed air so that a sudden retraction is
prevented
• Pay attention to emergency shutdown facilities.
• Pay attention to what will happen after an emergency stop or
abnormal stoppage. Ensure that nobody can be placed at risk or
be injured when equipment is restarted.
• When mounting loads, take measures to prevent impermissible
forces and torques.
• Choose a connection with a load that has its own guide
mechanism, and make sure that it is aligned sufficiently.
• During operation, avoid contact with the linear module.
• Use a suitable screw tightening torque for mounting the linear
module, or choose loads on the linear module in accordance
with the generally applicable guidelines for screw connections.