Priming - Taylor C706 Operator's Manual

Soft serve freezer
Hide thumbs Also See for C706:
Table of Contents

Advertisement

8. When a steady stream of sanitizing solution flows
from the prime plug opening in the bottom of the
freezer door, pull the draw handle down. Draw off all
of the sanitizing solution.
Figure 6-32
9. Once the sanitizer stops flowing from the door spout,
raise the draw handle. Press the WASH and PUMP
keys, canceling the beater motor and pump
operation.
Figure 6-33
Important! The machine must not be placed in Auto
mode until all sanitizing solution has been removed
from the freezing cylinder and proper priming
procedures have been completed. Failure to follow
this instruction may result in damage to the freezing
cylinder.
Note: Make sure your hands are clean and
sanitized before continuing these instructions.
Operating Procedures
10. Lubricate the mix feed tube O-rings located on the
end of the tube with the small hole on the side. Stand
the mix feed tube in the corner of the mix hopper.
Place the locking clip in position on the outlet fitting of
the pump.
10506

Priming

1. Place an empty pail beneath the door spout and
lower the draw handle. Make sure the prime plug is
still in the up position. Pour 2 gal. (7.6 L) of fresh mix
into the hopper and allow it to flow into the freezing
cylinder. This forces out any remaining sanitizing
solution. When full strength mix is flowing from the
door spout, raise the draw handle.
Note: Use only fresh mix when priming the freezer.
2. Once a steady stream of mix starts to flow from the
prime plug opening in the bottom of the freezer door,
push down the prime plug.
Model C706
OPERATING PROCEDURES
Figure 6-34
Figure 6-35
12334
6
10507
6-9

Hide quick links:

Advertisement

Table of Contents
loading