OPERATING PROCEDURES
Important! Failure to remove all sanitizing solution may
result in damage to the freezing cylinder.
3. When the mix stops bubbling down into the freezing
cylinder, insert the mix feed tube. Remove the locking
clip from the outlet fitting of the mix pump. Insert the
outlet end of the mix feed tube into the mix inlet hole
in the mix hopper. Place the inlet end of the mix feed
tube into the outlet fitting of the mix pump. Secure it
with the locking clip.
4. Press the AUTO key. When the machine cycles off,
the product is at serving viscosity.
6
5. Fill the hopper with fresh mix. As the mix level comes
in contact with the mix level sensing probe on the
front wall of the hopper, the MIX LOW indicator light
will shutoff.
Note: The MIX REF indicator light will come on,
showing the mix refrigeration system is maintaining
the mix in the hopper.
6. Place the mix hopper cover in position.
6-10
Figure 6-36
Figure 6-37

Closing Procedure

To disassemble your machine, the following items are
needed:
Two cleaning pails
Sanitized stainless steel rerun can with lid
Necessary brushes (provided with freezer)
Cleaner
Single-service towels
Draining Product from Freezing
12335
Cylinder
1. Press the AUTO key, canceling compressor and
beater motor operation. Press the MIX REF key,
canceling the mix hopper refrigeration system.
2. Remove the hopper cover and take it to the sink for
cleaning.
3. If local health codes permit the use of rerun, place a
sanitized, NSF International approved stainless steel
rerun container beneath the door spout. Press the
WASH and PUMP keys. Lower the draw handle and
drain the remaining product from the freezing
cylinder and mix hopper. When the flow of product
stops, press the WASH and PUMP keys and close
the draw valve. Place the sanitized lid on the rerun
container and place it in the walk-in cooler.
13112
Note:
If local health codes do not permit the use of
rerun, the product must be discarded. Drain the product
into a pail and properly discard it.
ALWAYS FOLLOW LOCAL HEALTH CODES.