Taylor C606 Operator's Manual

Taylor C606 Operator's Manual

Combination freezer
Table of Contents

Advertisement

Original Operating Instructions
059714-M
Model C606
Combination Freezer
OPERATOR'S
MANUAL
May, 2004 (Original Publication)
(Updated 8/4/15)

Advertisement

Table of Contents
loading

Summary of Contents for Taylor C606

  • Page 1 OPERATOR'S MANUAL Model C606 Combination Freezer Original Operating Instructions 059714-M May, 2004 (Original Publication) (Updated 8/4/15)
  • Page 2 Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: Minimum Wire Ampacity: E 2004 Carrier Commercial Refrigeration, Inc.
  • Page 3: Table Of Contents

    ......... . . Model C606...
  • Page 4 ............Table of Contents Model C606...
  • Page 5 Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company a division of Carrier Commercial Refrigeration, Inc. 750 N. Blackhawk Blvd. Rockton, IL 61072 Model C606 Table of Contents...
  • Page 6 Notes: Table of Contents Model C606...
  • Page 7: To The Installer

    Uncrate the unit and inspect it for damage. Report hazardous moving parts as well as poor any damage to your Taylor Distributor. performance or damage to the equipment. This piece of equipment is made in the USA and has Note: All repairs must be performed by an USA sizes of hardware.
  • Page 8: Electrical Connections

    Electrical connections are made directly to the device to disconnect the appliance from the power terminal block. The terminal block is provided in the source must have an all-pole disconnecting device splice box located behind the right side panel. 130318 To the Installer Model C606...
  • Page 9: Refrigerant

    Refrigerant Taylor reminds technicians to be cautious of government laws regarding refrigerant recovery, In consideration of our environment, Taylor recycling, and reclaiming systems. If you have any uses only earth friendly HFC refrigerants. The HFC questions regarding these laws, please contact the refrigerant used in this unit is R404A.
  • Page 10: To The Operator

    The unauthorized use of alternate refrigerants will void your Taylor compressor warranty. It is the Note: Your Taylor warranty is valid only if the parts unit owner's responsibility to make this fact known to are authorized Taylor parts, purchased from the any technician he employs.
  • Page 11 Taylor will continue to monitor the industry and test To find out the current status of an alternate new alternates as they are being developed. Should refrigerant as it relates to your compressor warranty, a new alternate prove, through our testing, that it call the local Taylor Distributor or the Taylor factory.
  • Page 12: Safety

    We at Taylor Company are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture DO NOT operate the freezer unless it is built-in safety features to protect both you and the properly grounded.
  • Page 13 78 dB(A) when measured at a distance of experience with the appliance, in particular as far as 1.0 meter from the surface of the machine and at a safety and hygiene are concerned. height of 1.6 meters from the floor. 130318 Model C606 Safety...
  • Page 14: Operator Parts Identification

    Section 4 Operator Parts Identification Exploded View Figure 1 140624 Operator Parts Identification Model C606...
  • Page 15 GUIDE A.-DRIP PAN-MIX PUMP X48228 LADLE-1 OZ 033637-1 PANEL-REAR-LOWER 055959 PAN-DRIP 19-1/2 LONG 035034 PAN-DRIP-SIDE X56005 PLATE-DEC 056131-1 TRIM-CORNER-REAR-R 056692 PANEL-SIDE LEFT 055957 TRIM-CORNER-REAR-L 056693 FILTER-AIR-18.00LX13.50HX.70 052779-3 CASTER-4" 044106 CASTER-4" SWV 3/4-10 STEM 046437 W/BRAKE SCREW-1/4-20X3/8 011694 140624 Model C606 Operator Parts Identification...
  • Page 16: Front View

    Front View Figure 2 140624 Operator Parts Identification Model C606...
  • Page 17 FITTING A.-SYRUP JUG 36" X53353-BLU FITTING A.-SYRUP JUG 36" X53353-BRN GASKET-DRIP LIP 036435 FITTING A.-SYRUP JUG 36" X53353-RED *NOT SHOWN FITTING A.-SYRUP JUG 36" X53353-WHT CAP-ULTIMATE SYRUP 053040-BLU CAP-ULTIMATE SYRUP 053040-RED CAP-ULTIMATE SYRUP 053040-BRN CAP-ULTIMATE SYRUP 053040-WHT 140624 Model C606 Operator Parts Identification...
  • Page 18: Syrup Cabinet View

    058613 NUT-10-32 FLANGE LOCKNUT 020983 BLOCK-HINGE 058614 SCREW-10-32X3/8 SLTD 006749 MAGNET-CATCH ASSY. 016121 WASHER-#8 EXT TOOTH LOCK 000964 SCREW-4-40X3/8 SOCKET CAP 058317 SCREW-8-32X1/4 SLTD ROUND 016540 *PRIOR TO S/N K4091994, USE 058630 LATCH- DOOR-MAGNETIC. 140624 Operator Parts Identification Model C606...
  • Page 19: Syrup Pump & Tubes

    052916 FERRULE- .625 ID 053036 KIT A.-PERISTALTIC PUMP X54978 FITTING-PERISTALTIC PUMP 054526 TUBE (1 TUBE KIT) O-RING 1/2 OD x .070 024278 KIT A.-PERISTALTIC PUMP X54979 LINE A.-SYRUP X62426-8 TUBE (4 TUBE KIT) *NOT SHOWN Model C606 Operator Parts Identification...
  • Page 20: X57028-Xx Pump A. - Mix Simplified - Shake

    ADAPTOR - MIX INLET - SHAKE 054944 TUBE A.-FEED TUBE-SHK X55973 BLUE RING-CHECK-FEED-TUBE 056524 O-RING-11/16ODX.103W-RED 016132 (50 TO BAG) SLEEVE A.-MIX PUMP X44761 PIN-COTTER-HAIRPIN-1/8DIA 044731 *STANDARD CAP-VALVE BODY SHAFT IS -10. AVAILABLE IN OTHER SIZES 140624 Operator Parts Identification Model C606...
  • Page 21: X57029-Xx Pump A. - Mix Simplified - Soft Serve

    *NOTE: THE STANDARD PUMP IS X57029-12. OVERRUN CAN BE CHANGED HIGHER OR LOWER PIN-COTTER-HAIRPIN-1/8DIA 044731 BY SUBSTITUTING THE VALVE BODY CAP. THE HIGHER THE (-) THE HIGHER THE OVERRUN. SHAFT A.-DRIVE-MIX PUMP- X41947 HOPPER 140624 Model C606 Operator Parts Identification...
  • Page 22: X59304 Syrup Line Assembly - Thin Viscosity Syrup

    FERRULE-.650 ID NP BRASS 029834 VALVE-CHECK-DUCKBILL 500598 INSERT-QD-CPC-3/8 BARB 056675 FITTING-SYRUP NOSE .075 056649 SLOT O-RING-11MM ID X 2MM W 053890 GREEN (25 TO BAG) O-RING-11MM ID X 2MM W 053890 GREEN TUBE-NYLOBRADE 3/8IDX5/8 500038-9 FITTING-SYRUP ELBOW 056651 Operator Parts Identification Model C606...
  • Page 23: X56652 Syrup Line Assembly - Thick Viscosity Shake Syrup (Optional)

    DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. FERRULE-.625 ID 053036 VALVE-CHECK DUCKBILL 500598 FITTING BARB 056675 FITTING-SYRUP NOSE 056650 (LARGE SLOT) O-RING 500205 O-RING-11 MM GREEN 053890 HOSE-BEVERAGE 053052-9 (SYRUP HOLE PLUG) FITTING-SYRUP ELBOW 056651 Model C606 Operator Parts Identification...
  • Page 24: X58450 Syrup Line Assembly - Syrup-In-Bag Option

    O-RING 1/2 OD X .070 024278 COUPLING-QD MALE 1/4 BARB 058452 FITTING-MALE 054526 TUBE-VINYL 3/16 ID X 1/16 W 020940-8 (R30314) FERRULE- .625 ID NP BRASS 053036 HOSE-BEVERAGE 3/8 ID 053052-36 COUPLING-QD FEMALE 3/8 058451 Operator Parts Identification Model C606...
  • Page 25: Mix Hopper - Top View

    ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. SLEEVE A.-MIX PUMP X44761 HOUSING A.-AGITATOR X51661 (SOFT SERVE) PROBE A.MIX OUT X41348 PROBE A.-MIX LOW X42077 HOUSING A.-AGITATOR X51664 CAP-MAGNET 080826 (SHAKE) MAGNET A.-AGITATOR-INNER X41733 120522 Model C606 Operator Parts Identification...
  • Page 26: Accessories

    Accessories Figure 11 140624 Operator Parts Identification Model C606...
  • Page 27 LADLE-1 OZ-120D BEND 033637-1 KIT A.-PERISTALTIC PUMP X54978 TUBE CUP-DIVIDED SYRUP 017203 KIT A.-TOPPING PUMP X53795 TOOL-O-RING REMOVAL 048260-WHT SPARES LUBRICANT-TAYLOR HI PERF 048232 KIT A.-TUNE UP X49463-59 BOTTLE-WASH-PLASTIC 044818 DEFLECTOR-BLOWER 047912 EXHAUST TOOL-MIX PUMP SHAFT 057167 REMOVAL BOX-TOOL 15 INCH PLASTIC...
  • Page 28: X44127 Brush Kit Assembly

    YELLOW BRISTLE BRUSH 039719 WHITE BRISTLE BRUSH 013073 WHITE BRISTLE BRUSH 023316 (1” x 2”) (3” x 7”) WHITE BRISTLE BRUSH 014753 BRUSH-PUMP SPOUT 054068 (1-1/2” x 3”) WHITE BRISTLE BRUSH 033059 (1/2” x 3”) Operator Parts Identification Model C606...
  • Page 29: X53800-Brn/Tan Syrup Pump

    032758 SPRING-PLUNGER-SYRUP 032761 PUMP WASHER-NYLON 032760 PLUNGER 036578 SEAL A. X33057 NUT-PLUNGER 036577 NUT-LOCK-SYRUP PUMP 039680 PUMP A.-SYRUP HEATED X53798-SER SHALLOW 036579 NOTE: SHOWN FOR REFERENCE ONLY. NOT SUPPLIED WITH NEW UNITS. Figure 13 140624 Model C606 Operator Parts Identification...
  • Page 30: Beater Door Assembly - Shake Side

    Beater Door Assembly - Shake Side Figure 14 Operator Parts Identification Model C606...
  • Page 31 SEAL-SPINNER SHAFT 036053 BEATER A.-7 QT. FLUTED X50958 SPINNER 034054 BLADE O-RING 6” (FREEZER DOOR) 033493 BLADE A.-SPINNER X59331 DOOR A.-SHAKE SIDE X55825SER2 CAP-RESTRICTOR 033107 NUT-STUD-SHORT 055989 VALVE A.-DRAW 059000 O-RING SYRUP PORT 11 MM 053890 Model C606 Operator Parts Identification...
  • Page 32: Beater Door Assembly - Soft Serve Side

    (100 TO BAG) KIT A.-BEATER-FRONT X50350 O-RING-1/4 OD X .070W 50 015872 SHOES-BEARING DURO (25 TO BAG) BEATER A.-3.4QT-1 PIN X46231 NUT-5/16-24 FINISHED HEX 029639-BLK BLADE-SCRAPER-PLASTIC 046235 SCREW-ADJUSTMENT-5/16-24 056332 CLIP-SCRAPER BLADE 7 INCH 046236 140624 Operator Parts Identification Model C606...
  • Page 33: 059088 Tray-Parts-Shake Side

    O-RING -SYRUP PORT 11MM 053890 FITTING-SYRUP NOSE SEE PAGES ID GREEN 16 & 17 PLUG-SYRUP PORT 053867 RETAINER-SYRUP VALVE 054554 SPINNER 034054 O-RING 6” - DOOR 033493 BLADE A.-SPINNER X59331 DOOR A.-SHAKE X55825SER2 SEAL-SPINNER SHAFT 036053 Model C606 Operator Parts Identification...
  • Page 34: 059087 Tray-Parts-Soft Serve Side

    DRIVE SHAFT 032564 BEARING-FRONT 050348 SEAL-DRVE SHAFT 032560 NUT-STUD 055989 BLADE-SCRAPER 046235 O-RING (DRAW VALVE) 014402 CLIP-SCRAPER BLADE 046236 GASKET (FREEZER DOOR) 048926 BEATER A. X46231 VALVE A.-DRAW X55820 SHOE-FRONT HELIX- REAR 050346 DOOR A.-W/BAFFLE X57332-SER Operator Parts Identification Model C606...
  • Page 35: 056525 Tray-Parts-Pump-Simplified

    O-RING-DRIVE SHAFT 048632 O-RING-DRIVE SHAFT 048632 TUBE A.-FEED-HOPPER X55973 TUBE A.-FEED-HOPPER X55974 SHAKE SOFT SERVE O-RING 1-3/4 008904 O-RING 1-3/4 008904 O-RING-11/16 OD - RED 016132 O-RING-11/16 OD - RED 016132 AGITATOR A.-MIX HOPPER X44797 050621 Model C606 Operator Parts Identification...
  • Page 36: Important: To The Operator

    Indicator Light-Mix Out Keypad-Vanilla Flavor Switch-Power Keypad-Strawberry Flavor Standby-Soft Serve Keypad-Chocolate Flavor Standby-Shake Indicator Light-Mix Low Note: See the Manager's Menu on page 38 for additional key functions when the Calibration or Manager's Menu is displayed. Important: To the Operator Model C606...
  • Page 37: Symbol Definitions

    To better communicate in the International arena, symbols have replaced words on many of our = MENU DISPLAY operator switches, function, and fault indicators. Your Taylor equipment is designed with these International symbols. The following chart identifies the symbol definitions. = AUTO...
  • Page 38: Heat Mode Symbol

    (See Figure 21.) Figure 20 WARNING: Do not use metal objects to press the reset button. Failure to comply may result in severe personal injury or death. Figure 21 091002 Important: To the Operator Model C606...
  • Page 39: Shake Fill Level Adjustment

    Lamp Test, Lockout Data, overfilling, it may be necessary to adjust the sensor Configuration Data, and System Data. position. (See Figure 22.) (See Figure 23.) C602 / C606 UVC4 V01.01.000 lamp test Figure 23 Lamp Test: The control and software version is displayed and all of the LED's on the display panel are illuminated.
  • Page 40 130°F (54.4°C). timer. (See Figure 28.) (See Figure 31.) POWER SWITCH OFF TIME: 5:00 DO NOT DRAW 41.0 HOPPER 41.0 DO NOT DRAW 41.0 BARREL 41.0 Figure 28 Figure 31 120515 Important: To the Operator Model C606...
  • Page 41 Always comply with local guidelines for the < PRESS TO CLEAR maximum number of days allowed between brush clean cycles. (See the Manager's Menu for setting the Brush Clean interval, on page 44.) Figure 35 Model C606 Important: To the Operator...
  • Page 42 Once the timer counts down to zero, the thermistor failure.) lockout is cleared. Important: To the Operator Model C606...
  • Page 43 Once the freezer is unlocked by starting a heat page 47.) treatment cycle the HEAT symbol will illuminate and the following message will be displayed on the screen. (See Figure 41.) DO NOT DRAW DO NOT DRAW Figure 41 120515 Model C606 Important: To the Operator...
  • Page 44: Manager's Menu

    Menu was selected. However, the soft serve side control keys will not be lit and are non-functional when the Manager's Menu or Calibration Menu is displayed. Figure 46 Important: To the Operator Model C606...
  • Page 45 Selecting “EXIT FROM MENU” will exit the Select the CALIBRATION symbol to exit the Manager's Menu and return the control panel VERIFY CALIBRATION screen and return to the symbols to normal operation. Manager's Menu list. 120515 Model C606 Important: To the Operator...
  • Page 46 Other = Any draw termination that is not Pyro, Time, reset to zero when the machine is brush cleaned. or Oper (example: power switch turned off while (See Figure 52.) product is dispensing) 120515 Important: To the Operator Model C606...
  • Page 47 (See Figure 57.) month. Touch the CALIBRATION symbol accept the selection. (See Figure 60.) SET CLOCK DST START MONTH 08:00 05/15/2012 > Exit > Figure 57 Figure 60 120515 Model C606 Important: To the Operator...
  • Page 48 AUTO HEAT TIME screen. Select the CALIBRATION symbol to exit the Select the CALIBRATION symbol to exit the screen and return to the Menu. screen and return to the Menu. 120515 Important: To the Operator Model C606...
  • Page 49 TIME 14 DAYS advance the cursor and program the minutes No Changes Allowed setting. Press any Key Select the CALIBRATION symbol to return to the previous screen with the new time setting displayed. Figure 70 120515 Model C606 Important: To the Operator...
  • Page 50 > Enable HOPPER THERMISTOR BAD - Place the power Disable switch in the OFF position. Call your Taylor authorized service technician. Figure 72 HOPPER OVER TEMP - Place the power switch in the ON position and verify that the AUTO or STANDBY symbol is illuminated.
  • Page 51 GLYCOL THERMISTOR BAD - Place the power Listed below are the variable messages that may switch in the OFF position. Call your Taylor appear. authorized service technician. Faults Occurring Entering a Heat Treatment Cycle PRODUCT DOOR OFF - Place the power switch in the OFF position.
  • Page 52 . Scroll the screens in > Standard records the opposite direction by selecting the OPTIONAL Details Exit FLAVOR symbol . Exit the FAULT HISTORY screen and return to the menu by selecting the CALIBRATION symbol Figure 77 120515 Important: To the Operator Model C606...
  • Page 53 (B) temperatures recorded at the end of A high pressure cut-out condition occurred the Heat Treat Cycle and indicates the side (L or R) during the heat cycle. of the freezer. 120515 Model C606 Important: To the Operator...
  • Page 54 COOL The phase that refrigerates the mix until all four temperature zones are cooled below 41°F (5°C). HEAT TREAT CYCLE SOAK phase temps COOL phase temps > ALL phase temps Figure 84 150417 Important: To the Operator Model C606...
  • Page 55 Heat Cycle results screen can be selected. zone displayed is the left barrel (LB). HEAT RB HEAT LB 169.0 5/15 25.4 5/15 02:05 > Result > Next zone Exit Exit Figure 87 Figure 91 120515 Model C606 Important: To the Operator...
  • Page 56 The first screen contains the record will be displayed with the selection for the control and software version installed in the result screen. machine. (See Figure 95.) SOFTWARE VERSION COOL RB C602 / C606 UVC 20.0 5/15 04:15 VERSION V01.01.00 > Result >...
  • Page 57 Note: To cancel the UNFLAVORED DRAW screen, Exit the CURRENT CONDITIONS screen and return touch the OPTIONAL FLAVOR symbol to move the to the Menu by selecting the CALIBRATION symbol arrow to “NO”, and select the CALIBRATION symbol 120515 Model C606 Important: To the Operator...
  • Page 58: Operating Procedures

    Section 6 Operating Procedures Note: When lubricating parts, use an approved food grade lubricant (example: Taylor Lube HP). If you are disassembling the machine for the first time or need information to get to this starting point Note: To ensure that the mix does not leak out of in our instructions, turn to page 90, “Disassembly”...
  • Page 59 Engage lubricant. the shaft end firmly into the drive shaft socket. (See Figure 106.) Figure 106 Note: When properly seated, the beater will not protrude beyond the front of the freezing cylinder. Figure 108 Model C606 Operating Procedures...
  • Page 60 Insert and align the draw valve spinner assembly Figure 109 into the shake door as shown. (See Figure 112.) Step 9 Lubricate the smaller end of the driven spinner. (See Figure 110.) Figure 110 Figure 112 070228 Operating Procedures Model C606...
  • Page 61 (See actuator bracket. Install the handscrews (short Figure 116.) handscrews at the bottom of the door). Tighten equally in a criss-cross pattern to insure the door is snug. Do not over-tighten. Figure 114 Figure 116 Model C606 Operating Procedures...
  • Page 62: Freezing Cylinder Assembly - Soft Serve Side

    Snap the restrictor cap over the end of the door spout and install the syrup valve retainer pins. (See Figure 118.) Figure 119 Note: When lubricating parts, use an approved food Figure 118 grade lubricant (example: Taylor Lube HP). 040803 Operating Procedures Model C606...
  • Page 63 USE EXTREME CAUTION when handling the beater assembly. The scraper blades are very Note: The hole on the scraper blade must fit sharp and may cause injury. securely over the pin to prevent costly damage. 150416 Model C606 Operating Procedures...
  • Page 64 Step 11 assembly is in position over the drive shaft by Lightly lubricate inside of the top of the freezer door turning the beater slightly until the beater is properly valve cavity. (See Figure 128.) 150415 Operating Procedures Model C606...
  • Page 65 5 to 7-1/2 oz. (142 g. to 213 g.) of product by weight per 10 seconds. To INCREASE the flow rate, turn the adjustment screw CLOCKWISE. Turn the adjustment screw COUNTER-CLOCKWISE to DECREASE the flow Figure 130 rate. Model C606 Operating Procedures...
  • Page 66: Mix Pump Assembly

    Apply a thin layer of lubricant to the inside of the pump cylinder at the retaining pin hole end. (See Step 18 Figure 137.) Install the front drip tray and splash shield under the door spouts. (See Figure 135.) Figure 135 Figure 137 150415 Operating Procedures Model C606...
  • Page 67 Assemble the valve cap. Slide the red o-ring into the Step 7 groove of the valve cap. DO NOT lubricate the Insert the valve cap into the hole in the mix inlet o-ring. (See Figure 139.) adapter. (See Figure 141.) Figure 139 Figure 141 Model C606 Operating Procedures...
  • Page 68 (See Figure 143.) tube, and thoroughly lubricate. (See Figure 145.) Figure 143 Note: The head of the retaining pin should be located at the top of the pump when installed. Figure 145 Operating Procedures Model C606...
  • Page 69: Sanitizing - Shake Side

    (See Figure 147.) WATER AND FOLLOW THE MANUFACTURER'S SPECIFICATIONS. Step 2 Install syrup hole plugs in the syrup ports in the freezer door. (See Figure 149.) Figure 147 Figure 149 080716 Model C606 Operating Procedures...
  • Page 70 AUTO until all sanitizing solution has been secure with the cotter pin. Failure to follow this instruction could result in sanitizer spraying on the removed from the freezing cylinder and proper operator. priming procedures have been completed. 150619 Operating Procedures Model C606...
  • Page 71 Install the agitator back onto the agitator drive shaft Step 22 housing. Install the syrup valves and the restrictor cap. 150619 Model C606 Operating Procedures...
  • Page 72: Sanitizing - Soft Serve Side

    CAUTION! Install the pump end of the mix feed tube and Note: Be sure your hands are clean and secure with the cotter pin. Failure to follow this sanitized before going on in these instructions. 150619 Operating Procedures Model C606...
  • Page 73: Priming - Shake Side

    Secure with cotter pin. (See Figure 158.) (See Figure 159.) Figure 158 Note: You have just sanitized all food contact surfaces of the freezer. Figure 159 150619 Model C606 Operating Procedures...
  • Page 74: Priming - Soft Serve Side

    Select the AUTO symbol Step 2 Note: This procedure should be done 15 minutes Remove the agitator from the mix hopper and the before product is expected to be served. restrictor cap from the shake freezer door spout. 150619 Operating Procedures Model C606...
  • Page 75 Replace the hopper cover. (See Figure 162.) Figure 164 Note: To assure sanitary conditions are maintained, brush each item for a total of 60 seconds, repeatedly Figure 162 dipping the brush in the cleaning solution. 041008 Model C606 Operating Procedures...
  • Page 76 This action will force solution out of the adjacent port and down around the spinner. This procedure should be performed for at least 10 seconds per port. (See Figure 166.) Figure 166 Figure 168 041008 Operating Procedures Model C606...
  • Page 77 Step 3 Remove the agitator from the mix hopper. Step 4 Take the agitator and hopper cover to the sink for further cleaning and sanitizing. Step 5 Figure 170 Rinse these parts in cool, clean water. 080723 Model C606 Operating Procedures...
  • Page 78 There are three phases of the heat cycle: Heating, Holding and Cooling. Each phase has a time limit. If any one of the three phases fail to reach the proper Figure 172 temperatures within the time limit, the cycle will Operating Procedures Model C606...
  • Page 79: Daily Opening Procedures

    Sanitize the restrictor cap, syrup hole plugs, syrup Step 2 valve retainers, spout cap and o-ring, shake cup Place the topping heaters in the ON position by holder, front drip tray and splash shield, in this touching the topping heater symbols solution. Model C606 Operating Procedures...
  • Page 80 Step 7 hole 10 to 15 times. Dip the brush in sanitizing Install the restrictor cap on the freezer door spout. solution before brushing each port. (See Figure 178.) (See Figure 176.) Figure 176 Figure 178 040803 Operating Procedures Model C606...
  • Page 81 Using a shake cup filled with an approved 100 PPM sanitizing solution, rinse the syrup nose fitting thoroughly. Step 12 Using a clean, sanitized towel, gently wipe any syrup from the duckbill valve. Figure 182 050112 Model C606 Operating Procedures...
  • Page 82 OPTIONAL FLAVOR symbol will be illuminated. The screen will display the calibration menu options. (See Figure 184.) UNFLAVORED DRAW SYRUP CALIBRATION SYRUP PRIME > EXIT Figure 184 Figure 187 050112 Operating Procedures Model C606...
  • Page 83 Step 29 Install the shake cup holder, the front drip tray and the splash shield. Figure 190 041008 Model C606 Operating Procedures...
  • Page 84: Syrup System

    , the AUTO symbol on the Shake side, and the OPTIONAL FLAVOR symbol will be illuminated. (See Figure 192.) Figure 191 Note: This procedure should be performed 15 minutes prior to serving product. Figure 192 041013 Operating Procedures Model C606...
  • Page 85 Step 4 Disconnect the syrup valve from the freezer door. Step 6 Raise the syrup valve retainer and pull the valve Repeat steps 4 and 5 for the remaining syrup straight out. (See Figure 196.) flavors. 041008 Model C606 Operating Procedures...
  • Page 86 Select a Flavor pinched and there are no kinks in the tubing. < Press to clear Step 4 Place the feed tube into the full syrup container and replace the syrup container in the syrup cabinet. Figure 200 Operating Procedures Model C606...
  • Page 87: Syrup Topping Pump

    Step 12 Repeat steps 10 -11 for any other syrup lines to be primed, or exit the SYRUP PRIME mode by touching the CALIBRATION symbol Figure 202 Model C606 Operating Procedures...
  • Page 88 (See Figure 204.) Figure 206 Step 8 Remove the seal o-ring from the seal. (See Figure 207.) Figure 204 Step 6 Remove the spring and washer from the plunger assembly. (See Figure 205.) Figure 207 Operating Procedures Model C606...
  • Page 89 Step 2 Figure 209.) Insert the black shielded brush through the tip of the discharge tube. Move the brush back and forth to scrub the tip of the discharge tube. (See Figure 211.) Figure 209 Figure 211 Model C606 Operating Procedures...
  • Page 90 Insert the black shielded brush into the top side of (See Figure 215.) the outlet valve. Scrub this area, specifically around the steel ball. (See Figure 213.) Figure 213 Figure 215 Operating Procedures Model C606...
  • Page 91 Install the washer and spring onto the plunger Step 11 assembly. (See Figure 218.) Sanitize the parts in an approved 100 PPM sanitizing solution (examples: Kay-5® or Stera-Sheen®). Allow the parts to air dry after sanitizing. Figure 218 Model C606 Operating Procedures...
  • Page 92 Turn the discharge tube end as far as it will go. Tighten the knob by turning it clockwise to fully engage it into locking grooves on clockwise. the valve body. Operating Procedures Model C606...
  • Page 93: Manual Brush Cleaning

    This Procedure Must Be Completed Every Two (See Figure 222.) Weeks! ALWAYS FOLLOW LOCAL HEALTH CODES. To disassemble the Model C606, the following items will be needed: Two cleaning and sanitizing pails for each side of the freezer Necessary brushes (provided with freezer)
  • Page 94: Draining Product From The Freezing Cylinder

    Step 4 Step 9 Remove the hopper cover and agitator. Take these Repeat steps 2 through 7 for the soft serve side of parts to the sink to wash, rinse and sanitize. the freezer. 041008 Operating Procedures Model C606...
  • Page 95: Rinsing

    WASH symbol, cancelling the wash mode. (Note: The shake draw valve will Step 9 automatically close when the WASH operation is Repeat steps 2 through 7 with the sanitizing cancelled.) solution. 140718 Model C606 Operating Procedures...
  • Page 96: Disassembly - Shake Side

    Step 5 Remove the drive shaft seal from the drive shaft. Step 6 Remove the freezer door o-ring, front bearing, retainer pins, and the draw valve spinner assembly. Figure 230 Operating Procedures Model C606...
  • Page 97: Disassembly - Soft Serve Side

    Note: DO NOT attempt to remove the star design from the door. The star design is part of the door and is NOT a removable piece. Figure 231 Figure 233 050801 Model C606 Operating Procedures...
  • Page 98: Brush Cleaning

    Step 7 pump components and the small syrup holes in the Sanitize all parts in the sanitizing solution for a shake freezer door. minimum of 1 minute. Operating Procedures Model C606...
  • Page 99: Syrup System - Scheduled Maintenance

    Stera-Sheen®). USE WARM WATER AND FOLLOW THE MANUFACTURER'S SPECIFICATIONS. Step 4 Raise the retainer and remove the syrup valve from the freezer door. Place the valve in a pail located under the draw valve. Figure 237 Model C606 Operating Procedures...
  • Page 100 Wipe the outside of the tubes with a Step 1 clean, sanitized towel. Lubricate the o-rings on the syrup line fittings with Taylor Lube HP. For Syrup Bag System: Disconnect each syrup bag and clean the hose connector fitting with a clean, sanitized towel.
  • Page 101 Step 13 Using a shake cup filled with an approved 100 PPM sanitizing solution, rinse the syrup valve fitting thoroughly. 050112 Model C606 Operating Procedures...
  • Page 102 Step 29 Step 20 Clean the syrup cabinet interior with a clean, Remove the pick up tubes from the pail of sanitizing sanitized towel. Spray resistant areas with the solution and allow them to drain. sanitizing solution. Operating Procedures Model C606...
  • Page 103: Important: Operator Checklist

    6. The temperature of the mix in the mix hopper Deteriorated or cracked water lines should be and walk-in cooler should be below 40_F. replaced only by an authorized Taylor (4.4_C.). distributor. 051207 Model C606...
  • Page 104: Winter Storage

    Winter Storage If the place of business is to be closed during the Your local Taylor Distributor can perform this winter winter months, it is important to protect the freezer storage service for you. by following certain precautions, particularly if the Wrap detachable parts of the freezer such as building is subject to freezing conditions.
  • Page 105: Troubleshooting Guide

    Section 8 Troubleshooting Guide Model C606 Troubleshooting Guide...
  • Page 106 Troubleshooting Guide Model C606...
  • Page 107 Model C606 Troubleshooting Guide...
  • Page 108 Troubleshooting Guide Model C606...
  • Page 109 Model C606 Troubleshooting Guide...
  • Page 110 Troubleshooting Guide Model C606...
  • Page 111 Model C606 Troubleshooting Guide...
  • Page 112 Troubleshooting Guide Model C606...
  • Page 113 Model C606 Troubleshooting Guide...
  • Page 114 Troubleshooting Guide Model C606...
  • Page 115 Model C606 Troubleshooting Guide...
  • Page 116 Troubleshooting Guide Model C606...
  • Page 117: Parts Replacement Schedule

    Black Bristle Brush, 1” x 2” Inspect & Replace if Necessary Minimum Double-Ended Brush Inspect & Replace if Necessary Minimum Yellow Bristle Brush Inspect & Replace if Necessary Minimum Brush Set (3) Inspect & Replace if Necessary Minimum Model C606 Parts Replacement Schedule...
  • Page 118: Section 10 Limited Warranty On Equipment

    Taylor, through an authorized Taylor distributor or service agency, will provide a new or re-manufactured part, at Taylor’s option, to replace the failed defective part at no charge for the part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty for a Product failure.
  • Page 119 LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
  • Page 120: Limited Warranty On Parts

    Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails due to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency, will provide a new or re-manufactured Part, at Taylor’s option, to replace the failed defective Part at no...
  • Page 121 Parts or the units in which they are installed repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, or normal wear or deterioration.
  • Page 122: Taylor Company

    LEGAL REMEDIES The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.

Table of Contents