CHAPTER
4

Boom Sensor Mounting Locations

Sensor mounting locations may be influenced by the boom configuration. If an object enters the sensor's blind
range unexpectedly, a false echo return to the sensor could occur, causing the boom to drop and the sensor or
boom to be damaged. To ensure optimal operation of the UltraGlide system and to protect the sprayer boom,
the sensors should be mounted on the front side of the boom, 8 - 10" above the lowest hanging part of the
boom.
Illustration of Sensor's Blind Range
FIGURE 1.

Mount the Boom Sensors

Manual No. 016-0230-106
S ensor Installation
C h a p t e r 4
WARNING
The machine must remain stationary and
switched off, with the booms unfolded and
supported, during installation or maintenance.