Toro Line Painter 1200 Service Manual page 59

Hide thumbs Also See for Line Painter 1200:
Table of Contents

Advertisement

5. Tip tank support to gain access to spray pump (see
Tank Support in this section).
6. Disconnect suction and pressure hoses from spray
pump fittings (Fig. 31).
7. Remove three (3) flange nuts (item 4) and cap
screws (item 12) that secure spray pump to chassis.
8. Lift spray pump assembly from machine.
Installation (Fig. 30)
1. Position spray pump to machine chassis. Secure
pump to chassis with three (3) flange nuts (item 4) and
cap screws (item 12).
2. Connect suction and pressure hoses to spray pump
fittings.
3. Return tank support to upright position and secure
with flange head screws (see Tank Support in this sec-
tion).
4. Apply antiseize lubricant to drive shaft. Place square
key (item 10) in pump shaft. Slide pulley onto pump shaft
with the pulley hub away from pump. Secure pulley to
pump with cap screw (item 7), lock washer (item 8) and
flat washer (item 6). Tighten pulley set screws.
5. Install spray pump drive belt (see Spray Pump Drive
Belt Installation in this section).
6. Secure high tension lead to spark plug.
Line Painter 1200
3
2
1. Spray pump
2. Suction line (in)
Page 5 – 29
4
1
Figure 31
3. Filter
4. Pressure line (out)
Paint System

Advertisement

Table of Contents
loading

Table of Contents