Operation using the controller

The controller is factory set so synchronising will only be necessary if there is an error, or if the
controller has been purchased separately. Synchronising involves the controller sending a signal to
the fire so it can memorise the certified frequency that it operates on.
If the controller is not synchronised
Only perform if the controller is NOT
synchronised—fire will not operate when any of
the functions are selected on the controller.
1. Turn the power off at the power point for a
minimum of 30 seconds.
2. Ensure the controller is turned off, to turn off
press and release the PWR button once.
3. Turn the power on at the power point, the
power operation indicator on the control
panel will flash once. The controller can
now be synchronised with the fire.
Synchronisation MUST BE performed within 30
seconds of the power being turned on. If more
than 30 seconds has elapsed repeat steps 1-3.
4. On the controller in quick succession press
the following sequence of buttons:
P > T > T > UP
The controller display will show L/C (Learn
Code) for two seconds, then return to
the normal OFF state display. The power
operation indicator on the control panel will
flash once to indicate that synchronisation
has been accepted.
Turning on and off
Press the OK and PWR button at the same
time to ignite the fire. This is a safety feature to
reduce the chance of young children being able
to turn on the fire.
The fire first lights to pilot, then after a period
switches to the high setting.
To turn off, press and release the PWR button.
12 | Symmetry RDV3611 operation guide: 11158-C 03-20
Changing the temperature
The Symmetry has seven stages of
temperature and flame modulation, which
can be changed by using the UP and DOWN
buttons.
The temperature control range is 7-32 °C.
There is also a setting before 7 °C that is --°C.
This means no set temperature has been
programmed.
The 7 °C setting does not indicate cooling
functionality. The lower temperature range is for
cooler climates where room temperatures fall
below 7 °C.
Changing between modes
To change between manual, automatic, or
flame modes, press and release the A/M
button.
Changing between °C and °F
The thermostat display can be set to °C and °F.
The default setting is °C.
With the thermostat off, press the following
sequence:
P > T > T > A/M
Restoring factory default
To restore the factory default settings, with the
controller off, press the following sequence:
P > T > T > DOWN