Test operation and lighting sequence

It may take approximately two hours of operation for the burn media to achieve their full flame
pattern and glow. During the initial burning in period, some smoke and smell may be experienced.
The appliance should run on the high setting in a well ventilated room until these dissipate. It is
important to check the flame pattern during this time.
Abnormal flame pattern
Abnormal flame performance and/or pattern can indicate a problem with your fire, such as blocked
gas injectors, or that the burn media has shifted. There are some warning signs that could indicate
a problem.
-
Unusual smell from the appliance
-
Continued difficulty or delay in establishing a flame
-
Flame appears either very short or very long
-
Flame only burns part way across the burner
-
Severe soot building up on the inside of the glass door
Important
It is the responsibility of the installer to check that under normal conditions of the appliance, all flue
gases are exhausted to the outside atmosphere, and that there is no spillage of combustion gases
into the room.
If the appliance cannot be made to perform correctly please contact Rinnai.
Normal flame pattern

Installation checklist and customer handover

Complete the installation checklist in the customer operation guide, and make sure you leave the
guide with the customer. Explain to the customer about the use and care of the unit, and ensure
they understand the instructions and operation of the appliance.
26
| Evolve 952/1253 Installation Guide: 13115-F 06-22
Abnormal flame pattern
candling flames