Programming your controller

The clock must be set before the programmed timers will operate. Each day of the week can be
programmed for four periods—a total of 28 programmed periods.
Setting the clock
1. With the controller
off, press 'T' for two
seconds.
2. Using the UP and
DOWN buttons adjust
to the correct time.
Ensure you have the
correct time of day
((AM/PM). Press OK to
accept.
3. Repeat the process to adjust the minutes
and day of the week.
Week settings available
A weekday program can be set so the program
is used Monday to Friday. Similarly, a weekend
program can be set for Saturday to Sunday.
If you do nothing to change the programming
the default settings would be available if you
set it to automatic mode. When in this setting,
the heater will automatically turn on and off
depending on the temperatures set—similar to
an air conditioning unit.
DEFAULT SETTINGS
Time period
Start time
Period 1
6:00 am
Period 2
8:30 am
Period 3
5:00 pm
Period 4
10:30 pm
* If the room temperature falls below 15 °C, the unit will
turn on and stay on until the room temp. increases above
15 °C.
To revert back to the default settings, press the
following sequence of buttons:
P > T > T > DOWN
If you want to stop the fire from coming on at
all, for example, during the night and before
period 1, you can reduce the temperature
setting using the DOWN button until --°C is
reached. This means no set temperature has
been programmed and the fire will stay off until
the next period setting.
To begin programming
With the controller off, press and hold 'P' for
two seconds to start programming. PROG will
be displayed, 'Pd, and the time at which the
controller is currently set will flash. Period 1 can
now be set.
Setting the day of the week
1. Press and release the UP or DOWN button
UP
OK
A/M
T
P
PWR
2. To accept the selected day(s) of the week
DOWN
Setting the period starting time
1. After setting the day the AM/PM setting will
2. To accept, press OK. The minute setting will
Setting the temperature
1. After setting the time period the
Temp. °C
2. To accept press OK. P1 is now set for the
20 °C
15 °C*
21 °C
15 °C
3. Repeat the programming process for the
If you want to check what has been
programmed, press P for two seconds and
select OK to continuously cycle through the
settings for each period.
to change the day the week.
press OK.
flash. To set the P1 starting time, press and
release the UP or DOWN button for the
hour setting. Ensure that the AM/PM is set
correctly.
flash as in step 1, press OK to accept.
temperature will flash. Press and release
the UP or DOWN buttons for two seconds
to adjust.
chosen day(s) of the week. P2 will now be
displayed, this can be setup for the same
day(s) of the week.
remaining periods.
Symmetry RDV3611 operation guide: 11158-C 03-20 | 11