Chapter 2: An Overview of the PA300-CN
Programmable Active-Low Inputs
Control Pad Cable assembly P/N 17500063 includes 18-inch, 22 AWG wires for four active-low circuit inputs.
Each input circuit can be programmed to activate with an installer-supplied switch with a current capacity of
100 mA , the SSP3000 control pad, or with the two-way switches on the steering wheel of the Ford Police
Interceptor.
Control Pad Features
All buttons on the control pad glow when the system is on. Pressed buttons turn bright to indicate that the
function they control is active. The amber LEDs in the upper center of control pad the mimic these active
SignalMaster patterns: Left, Right, Center-Out, or Warn patterns 1 to 4. LEDs glow over the position in which
the slide switch is placed.
System Specifications
Input Voltage
Polarity
Operating Temperature Range
Standby Current
Dimensions:
Amplifier/relay module
Height with cover
Width
Length
Net Weight
Control pad
Height
Width
Length
Net Weight
Shipping Weight
Siren Specifications
Operating Current (no lamps on)
Frequency Range
Nominal Cycle Rate
Nominal Voltage Output
12
11 Vdc to 15 Vdc
Negative ground only
–40 °C to +65 °C
Less than 0.5 A
3.0 in (7.6 cm)
6.5 in (16.5 cm)
8.5 in (21.6 cm)
3.5 lb (1.1 kg) approx.
3.26 in (8.28 cm)
1.62 in (4.11 cm)
6.80 in (17.27 cm)
0.8 lb (0.36 kg)
7.1 lb (3.2 kg) approximate
10 A max. (13.6 V battery, 11-ohm load at high power)
725 to 1800 Hz
Wail: 15 cycles per minute
Yelp: 220 cycles per minute
Priority: 370 cycles per minute
64 V peak-to-peak (siren tones)