Technical Data
ELECTRICAL DATA
Power supply
Input voltage
Frequency
Protections (optional)
Some models do not include intern protections, therefore, the
required protections shall be placed upstream in the circuit. The
applicable regulations must be taken into account.
CONNECTORS
MODEL*
BY DEFAULT
eNext S
Type 2 Socket
eNext T
Type 2 Socket
(*) Please check availability with your local supplier
(**) Minimum cable cross section recommended for the maximum AC in-
put current. The final cross section must be calculated by a qualified
technician taking into account the specific conditions of installation.
1P+N+PE / 3P+N+PE
230VAC+/- 10% / 400VAC+/-10%
50Hz / 60Hz
MCB IEC 60898-1 (curve C) - includes shunt trip
DC 6mA leakage detector (MCB/RCBO with shunt trip
is required to open the circuit)
RCBO: RCD Type A + MCB - includes shunt trip
OUTPUT
CURRENT
32A
32A
MINIMUM
OUTPUT
CABLE CROSS
POWER
SECTION**
7,4kW
10mm
22kW
10mm
2
2
43