AC INPUT
AC Power supply
AC Voltage
Nominal input current
Nominal input power
Frequency
OUTPUT
Charge system
Sockets/ Plugs
Lock system
Maximum output power
Maximum output current
Output voltage range
ELECTRICAL PROTECTIONS
Overcurrent protections
Safety protection
ENERGY METERS
Accuracy class in active energy
Accuracy class in reactive energy
Meter standards
NETWORK
Ethernet
GENERAL
Enclosure rating
Enclosure material
Operating temperature
Operating humidity
RFID system
Display
Power limit control
Interface protocol
Net weight
OPTIONAL DEVICES
Mobile communications
RCD protection
Overvoltage protection
CIRCONTROL, S.A. – Innovació, 3 – 08232 – Viladecavalls (Barcelona)
Tel.: +34 937 362 940 – Fax: +34 937 362 941
Web: www.circontrol.com – E-mail:
CCL-PT3-SMART
400V
PLUG A
Mode 3
Type 2
22kW
32A
400V
RCD 30mA auto recovery (class A)
Class B – EN50470-3
Class 2 – EN62053-23
EN62052-11, EN62053-21, EN62053-23, EN61010-1
10/100BaseTX
Stainless steel
To 95% RH Non-condensing
ISO / IEC14443A / B
LCD Backlight double line text
Mode 3 PWM control according ISO / IEC 61851-1
Transient surge protector
ps-suport@circontrol.com
3P + N + PE
+/- 10%
AC
64 A
44kW
50 / 60 Hz
PLUG B
Mode 3
Type 2
Yes
22kW
32A
(3P + N + PE)
AC
MCB
IP54 / IK10
-30 to +45ºC
OCPP / XML
65Kg
3G / GPRS
RCD class B
25