At Command - Queue Parameter Value Frame 0X09 - Digi XTend vB DigiMesh XTP9B-DPM-001 User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

Frame fields
Start delimiter
Length
Frame type
Frame ID
AT command
Parameter value (NH2 = two network hops)
Checksum

AT Command - Queue Parameter Value frame 0x09

Description
This frame allows you to query or set device parameters. In contrast to the AT Command (0x08) frame,
this frame queues new parameter values and does not apply them until you issue either:
The AT Command (0x08) frame (for API type)
l
The AC command
l
The device immediately returns the register queries (parameter value readings).
Format
The following table provides the contents of the frame. For details on frame structure, see
specifications on page
XTend vB DigiMesh RF Module User Guide
60.
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x05
3
0x08
4
0x52
5
0x4E (N)
6
0x48 (H)
7
0x02
8
0x0D