Operate in API mode
AT Command - Queue Parameter Value frame - 0x09
Description
This frame allows you to query or set device parameters. In contrast to the AT Command (0x08)
frame, this frame queues new parameter values and does not apply them until you issue either:
The AT Command (0x08) frame (for API type)
n
The AC command
n
When querying parameter values, the 0x09 frame behaves identically to the 0x08 frame; the response
for this command is also an AT Command Response frame (0x88).
Format
The following table provides the contents of the frame. For details on frame structure, see
specifications.
Frame data fields
Frame type
Frame ID
AT command
Parameter value
(BD7 = 115200 baud)
(optional)
XBee3® 802.15.4 RF Module User Guide
Offset
Description
3
0x09
Identifies the data frame for the host to correlate with a
4
subsequent response (0x88). If set to 0, the device does
not send a response.
5-6
Command name: two ASCII characters that identify the AT
command.
7-n
If present, indicates the requested parameter value to set
the given register. If no characters are present, queries
the register.
Frame descriptions
API frame
69