7.16.2 Service-Menu (Code 111) display of actual pressure

Taste
Display
5xMODE
123
11xDOWN
111
1xMODE
Ser
1xMODE
A.Pr
1xMODE
xx.x (xx
1xMODE
P.to
1xMODE
xx.x (xx
1xMODE
P.Sy
1xMODE
xx.x (xx
1xMODE
P.Pu
1xMODE
xx.x (xx
1xMODE
- - -
* If the set temperature unit is °C, the pressure is displayed in bar; with °F, it is displayed
in PSI.
7.17 Interface – menu (Code 130
Key
Display
5xMODE
123
7xUP
130
1xMODE
SSt
1xMODE
Pro
1xMODE
1xMODE
Hd
1xMODE
1XMODE
HSt
1xMODE
1xMODE
bd
Tempro basic C 90 & Tempro primus C 90
Funktion
Code 111
Service-Menu
Current pressure (active pressure)
*
) pressure at 1/10 bar (at 1 PSI
total pressure (total pressure)
*
) pressure at 1/10 bar (at 1 PSI
System pressure (system pressure)
*
) pressure at 1/10 bar (at 1 PSI
Pump- (flow-) – pressure (pump pressure) .
difference from "P.to"
*
) pressure at 1/10 bar (at 1 PSI
End
Function
Code 130
COM-Menu (serial interface)
Protocol
Key
Display Function
UP /
oFF
Down
P2
Hardware
Key
Display Function
UP /
oFF
Down
232
85.2
85.4
CL
manufacturer
Key
Display Function
UP /
Arb
Down
BtF
biL
boy
dE
Eng
Hus
AFF
net
tYo
Baudrate
*
)
*
)
*
)
and
"P.Sy"
*
)
no protocol activated
P2-protocol (the only supported protocol from
this device)
no interface selected
RS232
RS 485.2
RS 485.4
20 mA – interface (current loop)
Arburg
Battenfeld
Billion
Dr.Boy
Demag
Engel
Husky
Kraus Maffei
Netstal
Toyo
BASIC & PRIMUS C90 V 3.0 english / 10.04.2012