6.5 Procedure for exchanging tools Tempro basic C 90

Start device with main switch position 2
Cool down device with cooling-down function button (at least below 80°C)
Hold push button Q2 on operating panel down for as long as empty suction is
required
Switch off device (main switch position 0)
After tool change start device into operation and deactivate cool-down function
again.

6.6 Procedure for exchanging tools Tempro primus C 90

Using the cooling down function key, device in pressure temperature control mode
(at least below 80°C)
- Switch off device (main switch position 0)
- Start device with main switch position2 for the duration of evacuation
- Temperature control medium is sucked from tool *)
- Switch off device (main switch position 0)
After tool change, start device and switch cooling down function off again
*) For the evacuating process, a capacity of 3 l is available in the tank. When this
volume is exceeded, the stabilizing liquid enters the overflow pipe and flows out of
the stabilizer !
Tempro basic C 90 & Tempro primus C 90
For the evacuating process, a
capacity of 3 l is available in the
tank.
When
this
exceeded,
the
stabilizing liquid
enters the overflow pipe and flows
out of the stabilizer !
In order to suck the mould empty,
key Q2 must be kept pressed so
that the vent valve remains open.
BASIC & PRIMUS C90 V 3.0 english / 10.04.2012