LED flashing
Safety temperature exceeded (ref. 7.13)
Leakage (max. filling time exceeded)
Sensor breakage (where control is performed)
Beyond tolerance range
Maintenance alarm (not for Option „Flow indication")
PUMP flashes current consumption too high (motor protection relay has
tripped)
If the SET2 LED flashes this is not an error message, only the switched-on
cooling-down function is indicated.
Tempro basic C 90 error message:
Moreover, a potential-free alarm contact (changeover switch) is activated which
can be reset by pressing any key. (3-pole plug at stabilizer front)
Admissible contact load: 1A at 24V DC / 120V AC

7.13 Safety temperature limiter

This device is equipped with a safety temperature limiter which is independent
from the regulation or the control system and which switches off the control of the
heating security system if the safety temperature is exceeded (max. 130°C).
The limiter works on the principle of expansion of liquids in case of overheating
Make sure that the distributing main to the limiter is not bent or otherwise
damaged when the heating element is exchanged and whenever works are carried
out at the stabilizer.
Tempro basic C 90 & Tempro primus C 90
BASIC & PRIMUS C90 V 3.0 english / 10.04.2012
Page 30

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tempro basic C 90 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tempro primus c 90

Table of Contents

Save PDF