Operation; Changing Values - Wittmann Tempro basic C 90 Translation Of Original Operating Manual

Table of Contents

Advertisement

7 Operation

The wiring of the temperature stabilizer is designed for a right-hand 3-phase
network.
In main switch position 1 the pump is running in pressurized operation.
(Right-hand orientation)
Check: Fan wheel of the pump motor is running in arrow direction. If this is not the
case, two phases in the plug of the main connection must be interchanged.
The stabilizer has an operating panel with status and input display.
If no key is pressed for more than 25 seconds, invariably the current actual value
and stabilizer status are displayed.
In most cases the "short overview" will be sufficient for operation which is very
simple.
A detailed description for every single entry is given below.
In all of the following operating descriptions, those keys and displays are
emphasized in the figures which are of importance for the respective functions.

7.1 Changing values

Status display
LED illuminated means "function active"
LED flashing means "error"
To switch the equipment "ON" and "OFF" see chapter 7.9
Tempro basic C 90 & Tempro primus C 90
In general, the following information is
essential for changing values:
Press key
change values.
:
to select and keys
BASIC & PRIMUS C90 V 3.0 english / 10.04.2012
Page 23
and
to

Hide quick links: