Connecting the SmarTrax Hydraulic Valve

Place a solenoid gasket (included in the packet with the console cable harness) on the solenoid installed in
1.
port '1A' on the SmarTrax hydraulic valve (P/N 334-0003-087).
Locate the connector labeled 'LEFT' on the SmarTrax console cable harness (P/N 115-0171-775).
2.
Insert the connector labeled 'LEFT' to the solenoid installed in port '1A' on the SmarTrax hydraulic valve.
3.
Tighten the bolt on the solenoid connector to secure the connection and to help prevent moisture
4.
penetration.
Repeat step 1 through step 4 to connect the 'RIGHT' connector to the solenoid on port '1B'.
5.
Solenoid Connections on the SmarTrax Valve
FIGURE 1.
Solenoid
Connections
Manual No. 016-0190-098
W iring and Electrical
C h a p t e r 5
Connections
CAUTION
Ensure that the power cable is the last cable
connected.
Do not reverse the power leads. Doing so will
cause severe damage to the equipment.
Ensure the leads are connected to the correct
polarity.