Safety and requirements for product use
1

Safety

1.1

General safety information

• Observe the general safety information in the corresponding chapters.
Specific safety regulations can be found immediately before the task instructions.
Note
Damage to the product from incorrect handling.
• Switch off the supply voltage before mounting and installation work. Switch on sup-
ply voltage only when mounting and installation work are completely finished.
• Never unplug or plug in a product when powered!
• Observe the handling specifications for electrostatically sensitive devices.
1.2

Intended use

The bus node CPX-FB37 is intended exclusively for use in CPX terminals, as a participant in the EtherCAT
fieldbus system, and it may only be used as follows:
– in excellent technical condition
– in original status, without unauthorised modifications
– within the limits of the product defined by the technical data (
– in an industrial environment
Note
In the event of damage caused by unauthorised manipulation or other than intended
use, the guarantee is invalidated and the manufacturer is not liable for damages.
Warning
Danger of electric shock from voltage sources without protective measures.
• Use only PELV circuits in accordance with IEC/EN 60204-1 (Protective Extra-Low
Voltage, PELV) for the electric logic supply.
• Observe also the general requirements for PELV circuits in accordance with
IEC/EN 60204-1.
• Use only voltage sources that ensure a reliable electric separation of operating
voltage in accordance with IEC/EN 60204-1.