3.1.1 Installing Hydraulic Components – M205 With Quick Couplers
NOTE:
Union fittings (MD #252232) supplied in the kit are NOT used on M205 Windrowers equipped with quick couplers.
1. Install female coupler (A) (MD #138345) onto header
PRESSURE hose (B).
2. Install male coupler (C) (MD #138344) onto header RETURN
hose (D).
3. Connect PRESSURE coupler (A) to inboard steel line
coupler (B).
NOTE:
For reference, the other end of the pressure hose is
connected to split flange clamp (C) on the hydraulic motor.
4. Connect RETURN coupler (D) to outboard steel line
coupler (E).
NOTE:
For reference, the other end of the return hose is
connected to fitting (F) on the hydraulic motor.
5. Close coupler lock assembly (G) over couplers and secure
with pin (H).
215276
INSTALLATION INSTRUCTIONS
Figure 3.7: M205 equipped with Quick Couplers
Figure 3.8: Header Pressure and Return Connections