MacDon R113 Installation Instructions Manual page 28

Rotary disc header m205 compatibility kit
Table of Contents

Advertisement

Table 4.1 Troubleshooting (continued)
Problem
Symptom: Rotary disc header does NOT drive when engaged
Symptom: Power Limiter Module LED is flashing instead of solid
Either the power supply
or the wires are
reversed on the input or
output PWM valve
control wires.
215276
Solution
NOTE:
PWM valve control harness (MD #256652) has been designed to
ensure that correct polarity and circuit integrity is maintained.
If this problem condition occurs, confirm the input and output
wires are installed in the correct connector cavities on harness
MD #256652. Start with connectors P110 and P113.
APPENDIX
22
Refer to
Refer to 256652 on
Figure
4.1, page
23.
Revision A

Advertisement

Table of Contents
loading

Table of Contents