Installing Hydraulic Components - M205 Without Quick Couplers - MacDon R113 Installation Instructions Manual

Rotary disc header m205 compatibility kit
Table of Contents

Advertisement

3.1.2 Installing Hydraulic Components – M205 Without Quick Couplers
NOTE:
Quick couplers (MD #138344) and (MD #138345) supplied in the kit are
NOT used on M205 Windrowers not equipped with quick couplers.
1. Install union fitting (A) (MD #252232) onto header pressure
hose (B).
2. Install union fitting (C) (MD #252232) onto header return
hose (D).
3. Connect PRESSURE hose with union fitting (A) to inboard
steel line (B).
NOTE:
For reference, the other end of the pressure hose is
connected to split flange clamp (C) on the hydraulic motor.
4. Connect RETURN hose with union fitting (D) to outboard
steel line (E).
NOTE:
For reference, the other end of the return hose is
connected to fitting (F) on the hydraulic motor.
5. Connect case drain hose (G) to 1/2 in. male flat face
fitting (H).
6. Proceed to
3.2 Checking Speed Sensor, page
215276
INSTALLATION INSTRUCTIONS
Figure 3.11: Header Hoses and Union Fittings
12.
Figure 3.12: Header Hydraulic Connections
11