Arming Mode

The GSC3750 can be connected to 1 Active Alarm IN and up to 3 Passive Alarm IN inputs. Each detector
input is linked to a Zone that can be set with different Alarm Action (instant, delayed, 24h alarm).
An arming profile (Outdoor, Indoor, Sleeping or customer) is set of zones.
User can arm the alarm profile via LCD Menu from the Arming Mode by simply scrolling the options.
First step is to configure the zone, so proceed from the Settings Menu → Features → Zone Settings
1. Tap the first Zone to Edit
2. You may set a new Zone Name (Not mandatory).
3. Set Zone Type depending on the alarm input device used (Infrared, Smoke, Gas...etc.)
4. Depending on the alarm input type you can set it to either NO or NC on NO/NC.
5. Set the Alarm Type to either choices: Instant Alarm, Delayed Alarm or a 24h Alarm:
Instant Alarm: the zone will alarm when triggered immediately.
Delayed Alarm: The Enter Delay and Exit Delay will be applied.
24h Alarm: the zone will be armed for 24h.
Notes:
Both the Entering/Exiting Delay duration got a range from 0s to 60s.
The GSC3570 supports up to 4 zones.
Once the Zone(s) is configured, proceed from Features → Arming Mode:
On each Profile (Outdoor, Indoor, Sleeping, Custom) User can enable the zones.

Figure 15: Features: Zone Settings

GSC3570 User Manual
Version 1.0.3.1
P a g e
|
27