GSC3570 Connection & Wiring Diagrams - "Fail Safe" Electric lock, Power Supply and Wi-Fi
Figure 10: Fail Safe" Electric lock, 3rd Party Power Supply, Wi-Fi
Connecting GDS37xx with GSC3570
The GSC3750 can be configured with up to 10 GDS37xx devices allowing two doors remote control per
GDS, the configuration is done as follow:
Web interface configuration:
1. Access Settings→ External Service.
2. Select Account on which the remote door opening with softkey will be applied on.
3. Enter name of the GDS unit in System Identification. (not a mandatory field)
4. Set GDS SIP Number (or IP address in case of the peering scenario) on System Number.
5. Enter Door 1 name. (not a mandatory field)
6. Enter the Remote PIN to Open Door 1 configured in the GDS in Door 1 Access Password.
7. Enter the Remote PIN to Open Door 2 configured in the GDS in Door 2 Access Password.
8. Click on Save and Apply.
GSC3570 User Manual
Version 1.0.3.1
P a g e
|
23