24 June 1994

1.17 TRANSFER FAILURE

– Problem –
Poor image transfer or separation jams occur continuously.
– Possible Causes –
1. The transfer or separation corona wire/casing is dirty.
2. Improper transfer on separation corona output.
3. Damp paper.
4. Extremely high humidity and temperature.
– Action –
1. Clean around the Transfer/Separation unit.
2. Check the corona current and adjust if necessary.
3. Instruct the customer to keep paper in a dry place.
4. The pre-transfer lamp (PTL) is available as an optional service part.
Install the PTL by following the procedure described in section 5.