3.Preventive Maintenance
Paper Transfer Quality Standards
Printer
Item
Registration
Skew
Curling after
fusing
ADF
Item
Registration
Main Scan: 0 ± 2.0 mm
Sub Scan: 0 ± 1.5 mm
Skew
Main Scan: ± 1.1% (± 2.2 mm/200 mm)
Sub Scan: ± 1.0% (± 2.8 mm/200 mm)
These standards are determined using the standard paper with the standard conditions. The values
may change depending on environmental conditions such as temperature, humidity, and paper type.
24
Specification
Single Side:
Main Scan: 0 ± 2.0 mm
Sub Scan: 0 ± 1.5 mm
Duplex:
Main Scan: 0 ± 2.0 mm
Sub Scan: 0 ± 1.5 mm
Single Side:
± 1.0 mm/200 mm or less (B5 SEF or
more)
± 1.0 mm/100 mm or less (Less than B5
SEF)
Duplex:
± 1.0 mm/100 mm or less
10 mm or less (In an office
environment)
20 mm or less (In other environments)
Specification
Remarks
Reference value when using the
bypass tray:
Main Scan: 0 ± 3.5 mm
Sub Scan: 0 ± 2.5 mm
Reference value when using the
bypass tray:
± 1.0 mm/50 mm
Remarks
When 100% printing