Control Modes; One Act Flood (Manual Control) - SHOWTEC ACT Flood 80 RGBW Manual

Hide thumbs Also See for ACT Flood 80 RGBW:
Table of Contents

Advertisement

ACT Flood 80 RGBW

Control Modes

There are 2 modes:

One ACT Flood (Manual Control)

01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02) Secure the device with a safety cable (order code 70140 / 70141).
03) Plug the end of the electric mains power cord into a proper electric power supply socket.
When the ACT Flood is not connected with a DMX cable, it functions as a stand-alone device. It can be
controlled via the manual dimmer control or the menu settings.
Manual dimmer control
01) Select the option Rotary Knob in the Manual Settings menu. Refer to 2. Manual Settings on page 17
for more information.
02) Exit the submenu and return to the start screen. The start screen shows now the following:
03) Turn the manual dimmer control (5) to adjust the intensity of the light. The adjustment range is
between 0 and 255 (from 0 to 100 %). The current value of the dimmer is displayed on the screen.
Note: If you do not return to the start screen you cannot adjust the dimmer. The manual dimmer control
(5) is not functional, if you do not exit the menu and return to the start screen.
Note: In this mode you can control only the intensity of the light. It is not possible to add strobe effect.
Manual color control
01) Select the option Rotary Knob in the Manual Settings menu. Refer to 2. Manual Settings on page 17
for more information.
02) Exit the submenu and return to the start screen. The start screen shows now the following:
03) Turn the manual color control (4) to adjust the intensity of the light.
The adjustment range is:
Red, Green, Blue, White, Pink, Magenta, Yellow, Orange, Cyan, 2800K, 3200K, 4400K, 5600K, 7200K,
10000K.
The current color is displayed on the screen.
Note: If you do not return to the start screen you cannot adjust the color control. The manual color
control (4) is not functional, if you do not exit the menu and return to the start screen.
Note: In this mode you can control only the color of the light. It is not possible to add strobe effect.
Order code: 34040
Manual control
DMX-512 (4CH, 7CH, 11CH)