Command
Function
Verbose mode
Set verbose mode
View verbose mode
NOTE:
Verbose mode will revert back to default in the event of a power cycle, disconnect from dataviewer, or disconnect from the Ethernet.
X2)
KEY:
= Verbose mode
Timeout Ethernet data port
Set current port timeout
View current port timeout
X2!
KEY:
= Timeout
SIS over SSH (port 22023)
Enable Echo
Disable Echo
View Echo status
X$
KEY:
= Enable or disable
Matrix Status
Information request
Slot/LC connector
information
Request part number
View power supply voltages,
unit temperature, fan speeds
and Power Supply status
View temperature of the unit
View status of power
supplies (Primary, Redundant)
View fan speeds
X!
KEY:
= Input number
X^
= I/O board type
X&
= I/O board slot number
X1*
= SFP modules installed
X2$
= Power supply voltage
X2%
= Temperature
X2^
= Fan speed
X2&
= Power supply status
X2*
= Maximum virtual video matrix size
X3%
= Audio input number
SIS Command
(Host to Device)
E X2)
}
CV
E
}
CV
0
1
= Clear/none (default),
= Verbose mode,
3
= Verbose mode and tagged responses for queries
E
X2!
}
0*
TC
E
}
0TC
The number of seconds before timeout on IP connections (min=
E
}
1ECHO
E
}
0ECHO
E
}
ECHO
0
1
= Disable,
= Enable (default)
I/i
Verbose mode 2/3
X&
}
0*
I
Verbose mode 2/3
N/n
S/s
Verbose mode 2/3
E
}
20STAT
Verbose mode 2/3
E
}
21STAT
Verbose mode 2/3
E
}
22STAT
Verbose mode 2/3
00
– Maximum number of inputs for your configuration (
0
= No board detected,
1
– Maximum number of slots (
0
= No SFP,
P = Primary is listed first, R = Redundant is listed second
Degrees in Fahrenheit and Celsius (example: xx.xF • xx.xC)
Revolutions per Minute (RPM) (example: xxxRPM)
0
= Power Supply inactive/Not installed,
2
= Power Supply failed/Installed
inputxoutput (example: 80x80)
00
– Maximum number of inputs or Expansion
50001
Analog
FOX3 Matrix 80x Switchers • SIS Configuration and Control
Response
(Device to Host)
X2)]
Vrb
X2)]
2
= Tagged response for queries,
X2!]
Pti0*
X2!]
]
Echo1
]
Echo0
X$]
X2*
X2*
X!
X3%
X^
V
X
• A
X
• S
1
X2*
X2*
X!
X3%
Inf00* V
X
• A
X
X1* X1* X1* X1* X1* X1* X1* X1* ]
X1* X1* X1* X1* X1* X1* X1* X1* ]
Inf
nn ]
nnnn
60-
-
X2$
X2$
X2%
X2^
X2^
X2^
P
R
1
2
•
•
•
•
•
X2$
X2$
X2%
X2^
Sts00
P
R
1
•
•
•
•
X2% ]
X2% ]
20Stat
X2$
X2$
]
P
R
•
X2$
X2$
]
22Stat
P
R
•
X2^
X2^
X2^
X2^
]
...
1
2
3
n
•
•
X2^
X2^
X2^
X2^
22Stat
...
1
2
3
•
•
1
= Active MM board,
10
80x
for
)
1
2
3
= MM SFP,
= SM SFP,
= Unknown SFP
1
= Power Supply active/Installed,
50004
-
Additional Description
If no data is received during the timeout
period, the Ethernet connection closes.
1
65000
30
300
, max=
[default=
=
Returns command entered with
response.
Returns response only.
X^
X^
]
...
2
n
X^
X^
X^
]
• S
...
1
2
n
X2^
X2&
X2&
]
...
3
n
P
R
•
•
X2^
X2^
X2^
X2&
X2&
...
2
3
n
P
•
•
•
80x has 3 fans
]
n
0
= untie)
2
5
= Active SM board,
= Unknown
30001
30008
40001
-
, Dante
seconds]).
]
R
40032
-
,
27
Need help?