REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
STEP
1
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number 48
Press CR.
3
Refer to the System Record Sheet and enter the required port
number.
Example: Port 00, enter 0 0.
4
Press # key. The system will display the present data as a
two-digit code: The first digit designates digit free or digit restrict.
The second digit is the station restriction code. Refer to the
System Record Sheet and change if required.
5
To Exit Program/Store Data
To store data, press CR.
A)
B)
Continue returning to step 3 until all data is recorded for this
program.
To exit this program, press # # CR.
C)
STEP
1
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number 50.
Press CR.
3
Enter 1. Refer to the System Record Sheet and enter the required
button/LED number.
Example: Button 01, enter 0 1.
4
Refer to the System Record Sheet and change button/LED status,
if required.
Press SPACE to move to next button/LED.
5
To Exit Program/Store Data
A)
To store data, press CR.
To exit this program, press # # CR.
B)
TABLE RM-AW
PROGRAM 48
STATION TOLL RESTRICTION CLASSIFICATION
ACTION
TABLE RM-AX
PROGRAM 50-1
LCR PARAMETERS
ACTION
-50-
DISPLAY/PRINTOUT
>MODE PROG
P
P 48
P48
P48 00
P48 00# 13
P48 00# 13
P48 ##
P
DISPLAY/PRINTOUT
>MODE PROG
P
P 50
P50
P50 1 01 N
P50 1 01 N
02 N
P50 1 01 N
02 N
P50 ##
P