Toshiba Strata DK 16 Installation And Maintenance Manual page 296

Toshiba digital key telephone systems installation and maintenance manual
Hide thumbs Also See for Strata DK 16:
Table of Contents

Advertisement

REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
STEP
1
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter the Program Number 45
Press CR.
3
Refer to the System Record Sheet and enter 8 or 9 for the
desired code number. The system will display the present
override code number.
4
Refer to the record sheet and enter a new number if required.
Example: 1234. Enter: 1 2 3 4.
5
To Exit Program/Store Data
A)
To store data, press CR.
To exit this program, press # # CR.
B)
TOLL RESTRICTION ALLOWED/DENIED AREA CODES ASSIGNED BY CLASS
STEP
1
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number 46
Press CR.
3
Enter class number (1 ~ 4).
Enter 2, 3, or 4 SPACE
4
• 2
— to add codes to memory (allow).
• 3
— to delete codes from memory (deny).
• 4 SPACE
— to display codes in memory (allowed codes).
5
Refer to the System Record Sheet and enter the area code or
area code group. Single
Press SPACE to enter more codes.
Press SPACE to temporarily store data. Press CR when
6
completed.
7
Continue returning to step 3 until all data input is completed for
this program.
8
To Exit this Program
Press # # CR.
TABLE RM-AR
PROGRAM 45-8 ~ 9
TOLL RESTRICTION OVERRIDE CODE
ACTION
TABLE RM-AS
PROGRAM 46–2 ~ 4
ACTION
*
. Group
.
-46-
DISPLAY/PRINTOUT
>MODE PROG
P
P 45
P45
P45 8 NNNN
P45 8 NNNN 1234
P45 8 NNNN 1234
P45 ##
P
DISPLAY/PRINTOUT
>MODE PROG
P
P 46
P46
P46
Class Number
P46
2, 3 or 4
ALLOW? or DENY?
P46 X Y
ALLOW
or DENY
P46
P46 ##
P