Toshiba Strata DK 16 Installation And Maintenance Manual page 262

Toshiba digital key telephone systems installation and maintenance manual
Hide thumbs Also See for Strata DK 16:
Table of Contents

Advertisement

REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
acters represent a program group or a particular
program, i.e., ALL, 03, 04, 10, 39, etc. For a printout
example, see Figure 6.
NOTE:
Programs are output only in the groups indi-
cated. To print out or review a program not
included above, use Program Mode proce-
dures.
9.04 Speed Dialing Dump: While in the dump
mode (see Paragraph 7), enter "REP" and two or
three characters and press CR. The characters
represent the speed dialing codes for either an
individual station, A L L (all stations and system
data) S Y S (system data only).
9.05 LCD Messages Dump: While in the dump
mode (see Paragraph 7), enter "MSG" and two or
three characters and press CR. The characters
represent stored messages for either an individual
station, A L L (all stations and system data) or
S Y S (system data only). For a printout example,
see Figure 7.
9.06 Tables provide a quick reference to the step-
by-step procedures to output the appropriate data.
10 TEST MODE
10.00 General
10.01 The remote test mode (see paragraph 7)
can be used to test STRATA DK8 or DK16 stations
CO LINE
NUMBERS
8
81
00
11111111
81
01
00000000
81
02
00000000
81
03
00000000
81
04
00000000
81
05
00000000
81
06
00000000
CO LINE 08
STATION PORT NUMBER
PROGRAM NUMBER
FIGURE 6
DATA DUMP PRINTOUT EXAMPLE
1:SELECT(LED ON)
1
CO LINE 01
-12-
and CO line circuits from an off-site location.
10.02 This testing function is accomplished by
accessing stations from the remote terminal, and
activating various buttons on digital and elec-
tronic telephones to make telephone calls, set
function buttons, change the system time and
date, etc. (see Figure 8 and Tables RM-BS ~ BV).
IMPORTANT!
Any digital or electronic telephone button
can be activated from the remote terminal
at any time while in the Test Mode (even
while the end user is using the telephone).
Therefore, caution must be used to prevent
service interruption or interference. The
Test Mode provides status tests to check
whether or not a station or CO line is in use.
The status checks should always be made
before performing other tests (see Table
RM-BS).
10.10 CO Line Testing
10.11 To test CO line transmission, two or three
CO lines must be available at the remote site (see
Figure 8 and Table RM-BU).
10.12 CO line testing is accomplished by using all
of the following two methods:
1) Establish a talk path between the two remote
stations (B & C) via a CO-to-CO connection
through STRATA DK8 or DK16.
>MODE DUMP
D MSG SYS
SYS
M60
OUT TO LUNCH
SYS
M61
IN A MEETING
SYS
M62
CALL
SYS
M63
BACK AT
SYS
M64
RETURN ON
SYS
M65
SYS
M66
SYS
M67
SYS
M68
SYS
M69
D
FIGURE 7
SAMPLE PRINTOUT OF SYSTEM MESSAGES