JUMPER WIRES:
TB1
TB2
5-8
4-5
6-7
HACU-120
117/VAC TO
117
12 VDC
VAC
POWER
SUPPLY
MDF
66 BLOCK
STATION CABLING
VOICE TIP
VOICE RING
DATA T1
DATA R1
JACKETED
25-PAIR
TWISTED PAIR
CABLE
24 AWG
PEKU
(CKT 1~8)
OR
PESU
(CKT 5~8)
NOTE:
See Section 100-816-206
for instructions on how to
cut the HHEU strap inside
the telephone.
FIGURE 7-11

DK16 HESB/ELECTRONIC TELEPHONE WITH LOUD RINGING BELL WIRING

HESB (REAR VIEW)
VOLUME CONTROL
INTERNAL
WIRING:
TBI
VOICE
1
6
2
1
1 2 3 4 5 6 7 8 9 10
3
3
4
4
6 5 4 3 2 1 6 5 4 3 2 1
VOICE
MODULAR
12V 0V
CONNECTORS
MAY BE USED
1 2 3 4 5
12V
R
BK
W
OCA
TIP
6 5 4 3 2 1
1 2 3 4 5 6
MODULAR
CORD
ELECTRONIC
TELEPHONE
6500-SERIES
(+) (RED)
(-) (GREEN)
VOICE TIP
VOICE RING
JUMPERS
NOT USED
DOOR PHONE
TB2
0V
VOICE TIP
VOICE RING
GN
R
(+)
Y
BK
BL
W
OCA
RING
6 5 4 3 2 1
1 2 3 4 5 6
STATION
GREEN
3
(-)
2
1
(+)
P601
HHEU
INSTALL HHEU CIRCUIT
CARD INTO BASE OF
ELECTRONIC TELEPHONE
PER INSTRUCTIONS IN
SECTION 100-816-206.
7-15
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
TB1
24 AWG
JACKETED
TWISTED
PAIR
FROM
ELECTRONIC
TELEPHONE
TO HESB
JACKETED
GN
(-)
Y
BL
HESC-65 or HESC-65A
CABLE
RED
OCA
DO NOT
STRAP
CUT OCA
STRAP OR
R607
R607