3 Startup
3.11 Start-up functions
3.11
Start-up functions
Disabled softkeys
3-76
The following start-up functions are implemented for axes with HLA:
S
Measuring functions
-
Measurement of valve control loop
-
Measurement of velocity control loop
-
Position control measurement
S
Function generator
S
Circularity test
S
Servo trace
S
DAC configuration
Fig. 3-28
Menu display "Start-up functions"
The softkey "Self-opt.AM/MSD" in the "Start-up functions" menu is also disabled
for axes with HLA since this is a special function for AM/MSD.
The "Aut. Controller setting" in the "Startup functions" menu is disabled for axes
with HLA since the algorithms it uses are designed for automatic controller set-
ting for electric digital drives.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Siemens AG, 2003. All rights reserved
02.99