RFL100 User Guide
In the Info mode:
• Display and LED are turned on if they have been turned off remotely.
• Data logger starts radio scanning immediately if it has shut down to save power.
• After showing the current measurement results and possible error codes, the data logger
shows the text INFO ON and the following additional information:
• If the data logger is connected to an access point:
• Signal strength indicator
• The currently connected VaiNet channel is shown, alternating with measurement
results and firmware version.
• Firmware version of the data logger.
• Serial number(s) of probe(s) detected at startup, shown in three separate segments.
• If one probe is used, the letters SN are shown before the number.
• If two probes are used, the letters SN1 and SN2 are shown before the numbers,
corresponding to the channels that are assigned to the measurements from the
probe. The serial numbers are shown simultaneously on the top and bottom lines
of the display.
After all information has been shown, the same sequence is repeated until Info mode is
disabled or 1 hour has passed.
4.2.1 When to use info mode
Info mode can be very useful when you have physical access the data logger. The following are
the main use cases:
1. Wake up the data logger from radio power save without power cycling it.
2. Verify serial numbers and channel assignments when two temperature probes are
connected using probe splitter.
3. Check the access point where the data logger is currently connected. You can determine
this from the VaiNet channel number if you know the channel assignments of the access
points.
4. Check the firmware version of the data logger without power cycling it.
5. Determine the signal quality of the current access point connection. When the data logger
is connected to an access point, you can move the data logger around and monitor the
signal strength indicator
connection quality is shown only for the current access point connection.
4.2.2 Turning on info mode
• Pen or a small screwdriver
1. Open the plug that covers the service port.
2. Push the small button next to the service port using a pen or a small screwdriver.
3. Verify from the display that the text INFO ON appears briefly.
32
is updated faster, approximately every 30 seconds.
that updates every 30 seconds in info mode. Note that the