3.1.2 Setup with two temperature probes
1
2
1
Power switch
2
Probe splitter
3
Latch of the battery cover
4
Instruction label with short version of this setup instruction
5
Probe connectors of the probe splitter
6
Temperature probes
7
Numbering labels for TMP115 probes (included in the probe mounting accessories)
• Two temperature-only probes of following models: HMP110T, HMP115T and
TMP115 (any combination)
• Probe splitter (Vaisala item code CBL210834)
• Optional: extension cable(s), to be connected between the probe splitter and
probe
• Compatible firmware and software versions: at least RFL100 firmware version
1.2.0, AP10 firmware version 3.0, and viewLinc 5.0.2.
CAUTION!
probe splitter. The procedure includes steps to label the probes to make it easy
to identify the channel assignment later. You can also use the info mode of the
RFL100 to check which probe serial number is connected to which channel.
3
4
You must follow the procedure below to set up RFL100 with the
Chapter 3 – Installation
5
6
7
23