2.3

PROGRAM MULTI VALVE UNIT (MVU)

Set MVU Buttons as Carbonated, Non-Carbonated, or Flavor Shot Only.
The MVU can be programmed to serve soda or plain water beverages as well as a flavor shot from
each of the beverage positions on the valve.
To enter the programming mode on the MVU and assign water type to each individual brand
(Carbonated or Non-carb):
A. Press both A and C brand buttons at the
same time on the MVU panel for five
seconds.
1. The "Pour/Cancel" LED will illuminate. The
"SHOT" LED will blink one time.
2. Brands that are enabled for drinks will
have illuminated LED's:
Lights on = non-carb
Lights flashing = carb
Lights off = no water (deactivated unless set
for shot)
B. Press a Brand button to change that
beverage from "water off" to "plain water
on".
1. LED will illuminate and stay on for non-
carb beverages.
C. Press the same brand button again to
switch from non-carb to carb.
1. Press the button one more time to turn the
water off for that valve (if position is used
for a flavor shot only).
D. Repeat this process for each brand.