Connection Of The Equipment; Start Up - lancer 2308 Series Installation And Service Manual

Cold carb ice cooled dispenser
Hide thumbs Also See for 2308 Series:
Table of Contents

Advertisement

C. After the counter cutout is made, lower the dispenser into the counter.
NOTE: In order to ensure unit drainage and proper carbonation, it is necessary for the dispenser to
be level, front to back and side to side.
D. Position the pump deck under the counter within close proximity to the dispenser. The pump
deck must be on a level surface and have adequate electrical utilities available.
1.7

CONNECTION OF THE EQUIPMENT

A. Position the CO
CO
gas tank and run the jumper line to the low pressure regulator.
2
B. Attach the CO
to the CO
inlet. The setting of the high pressure CO
2
Do not turn on CO
WARNING!
C. Position the syrup pumps in the desired location. Attach the CO
pressure regulator to these pumps.
D. Connect the syrup lines from the pumps to the appropriate inlets at the front of the unit. The
syrup inlets are identified at the bottom of the unit.
E. Connect the water inlet line to the pump. Complete the water line connection between the pump
and the water inlet to the carbonator at the bottom of the dispenser.
F. Provide a suitable drain in the plumbing system and attach the 3/4 inch (1.90 cm) diameter
schedule 40 PVC drains to it. The drip pan drainage outlet is located at the right rear of the unit.
The ice water drainage outlet is located at the right front of the unit.
G. Be sure to place the ice trap in the drain outlet inside the ice bin before filling with ice. This
device holds the ice away from the drain outlet, allowing the ice water to drain properly.
H. Plug in the transformer box to a standard 20 AMP, 110 VAC, single phase outlet. The unit will
internally convert the 110 VAC to 24 VAC.
1.8

START UP

A. After all connections to water, CO
leaks.
B. Be sure the Bag-In-Box contains syrup.
Do not operate the carbonator pump deck with the water supply turned off.
WARNING!
C. Turn on water. Open the pressure relief valve on the carbonator tank by flipping up the valve cap
lever, and hold it open until water flows from the relief valve. Close (flip down) the relief valve
and turn on the CO
D. To fill all lines with water, cycle the carbonator several times by operating the dispensing valves.
1. Ensure a good flow of plain water is established from each valve.
2. Turn on CO
3. Operate valves until unit gases out.
4. Plug in carbonator pump motor. Pump Deck will automatically start.
gas tank in the desired location. Assemble the high pressure regulator to the
2
gas line to the carbonator by attaching the line from the high pressure regulator
2
at this time.
2
gas, electrical power, and syrup pumps are made, check for
2
gas.
2
at source and ensure that the HP regulator is set at 75 PSIG.
2
gas regulator should be 75 PSI.
2
5
gas lines leading from the low
2
P.N. 28-0720/05

Advertisement

Table of Contents
loading

Table of Contents