Adjusting Water Flow - lancer 2308 Series Installation And Service Manual

Cold carb ice cooled dispenser
Hide thumbs Also See for 2308 Series:
Table of Contents

Advertisement

5. Activate carbonated water valves so that the carbonator pump cycles several times and a
good flow of carbonated water is established.
6. A low pressure gas regulator controls the flow of syrup to each dispensing valve. Connect
BIB connectors to BIB's. Set LP regulator to 65 PSIG. Activate all valves to purge air from
the syrup lines.
NOTE: The unit will cycle on for 5.5 seconds, shut down, and immmediately start again and run
for additional 5.5 second intervals until the water level reaches the probe.
E. The dispenser bin should now be filled with ice cubes one inch below the level of the door
opening.
1.9

ADJUSTING WATER FLOW

A. The water flow can be adjusted to either 1.25 ounces/second (37 ml/sec) or 2.5 ounces/second
(74 ml/sec) on all dispensing valves, using the following procedure.
NOTE: The unit should have ice on the cold plate for a least one hour before you attempt to brix the
valves. The drink temperature should be no higher than 40
is done after the unit has ice in the ice bin.
C. Slide the ID panel up until the flow controls are exposed (see below).
D. Remove the nozzle by twisting counterclockwise and pulling down.
E. Remove the diffuser by pulling down.
F. Install Lancer yellow syrup separator (PN 54-0031) in place of the nozzle.
G. Activate the dispensing valve to fill the separator syrup tube.
H. Hold a brix cup under the syrup separator and dispense water and syrup into the cup for four
seconds. Divide the number of ounces (ml) of water in the cup by four to determine the water
flow rate per second.
I. To obtain the proper flow, use a screwdriver to adjust the water flow control.
J. Repeat process for each valve.
P.N. 28-0720/05
FLOW CONTROL
SYRUP
Increase
Decrease
SODA LEVER
(Optional)
CUP LEVER
Valve Adjustments
o
F (4.4
I.D. PANEL
(Shown in
open position)
COVER SCREW
FLOW CONTROL
SYRUP
Increase
Decrease
COVER
DATE OF
MANUFACTURE
SERIES NO.
NOZZLE
6
o
C) when the ratio is set. This

Advertisement

Table of Contents
loading

Table of Contents