Page 1
SERIES 2400 -- FREE STANDING This manual supersedes Installation and Service Manual, 28-0058/02, dated 10/17/97 6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000 FAX SALES • NORTH AMERICA – 210-310-7245 • INTERNATIONAL SALES – 210-310-7242 • CUSTOMER SERVICE – 210-310-7242 •...
TABLE OF CONTENTS TABLE OF CONTENTS ............................i SPECIFICATIONS...............................i 1. INSTALLATION OF LANCER ICE COOLED DISPENSER................1 RECEIVING............................1 UNPACKING ............................1 SELECTING A COUNTER LOCATION ....................1 WATER SUPPLY ..........................1 ELECTRICAL SUPPLY ........................1 SYRUP CONTAINERS........................1 INSTALLATION OF THE UNIT......................2 CONNECTION OF THE UNIT ......................2 START UP ............................3...
If damage exists, have carrier note same on bill of lading and file a claim with the carrier. UNPACKING A. The Lancer ice cooled dispenser is shipped in a corrugated shipping carton. B. Remove the corrugated shipping carton from the unit. C. Remove parts from the ice compartment.
Remember that the unit can extend up to 23 inches (58.42 cm) below the counter, including the shipping risers, which Lancer recommends be left attached to the unit. Should the dispenser ever require removal, the shipping risers will protect the inlet tubes from being damaged.
carbonator pump on the carbonator. G. Provide a suitable drain in the plumbing system and attach the one (1) inch (2.54 cm) diameter schedule 40 PVC drains to it. The drip pan drainage outlet is located at the center rear of the unit.
G. Activate dispensing valve to fill separator syrup tube. H. Hold a Lancer brix cup under the syrup separator and dispense water and syrup into cup for four (4) seconds. Divide number of ounces (ml) of water in cup by four (4) to determine water flow rate per second.
(2) Cleaning and sanitizing should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning and sanitizing operations. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed. IMPORTANT Water lines are not to be disconnected during the cleaning and sanitizing of syrup lines to avoid contamination.
WARNING TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT ATTEMPT TO REMOVE SYRUP TANK COVER UNTIL CO PRESSURE HAS BEEN RELEASED FROM TANK. G. Disconnect CO supply hose from the water filled syrup tank. H. Prepare cleaning solution as described in Section 2.2 above. Fill a tank with cleaning solution. Connect syrup line to the tank.
valve removed from an empty Bag-in-Box package. B. Place end of syrup inlet line, with bag valve attached, in a clean container filled with clean, potable, room temperature water. C. Place waste container under applicable dispensing valve. Activate valve until water is dispensed.
D. Using clean, potable water, thoroughly rinse away the cleaning solution from the sides and surface of the casting. E. Using plastic sanitary gloves, soak a white cotton gauze cleaning rag in the sanitizing solution and wipe all surfaces in the ice compartment. NOTE Please note that a fresh water rinse cannot follow sanitization of equipment.
4. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS SERIES 2300 DROP-IN...
Page 13
SERIES 2300 DROP-IN (CONTINUED) ITEM PART NO. DESCRIPTION 42-0035 Tank Assy, High Performance 42-0036 Tank Assy, Standard Performance 30-5473/03 Tank Wrapper 51-1236/01 Rim Assy 30-7140 Lid, Ice Bin 19-0077 ® 19-0078 with Soda Lever ® 05-1074/01 Drip Tray 23-0797/02 Cup Rest 30-5424 Splash Plate 04-0459...
Page 15
SERIES 2400 FREE-STANDING ITEM PART NO. DESCRIPTION 42-0035 Tank Assy, High Performance 42-0036 Tank Assy, Standard Performance 51-0641/02 Tank Wrapper 51-5227/02 Rim Assy 30-7140 Lid, Ice Bin 19-0077 ® 19-0078 with Soda Lever ® 05-1074/01 Drip Tray 23-0797/02 Cup Rest 30-5424 Splash Plate 30-6052...
Page 17
SERIES 2300 DROP-IN WITH PLUG IN TOWERS (CONTINUED) ITEM PART NO. DESCRIPTION 1 42-0048 Tank Assy 2 30-5473/03 Tank Wrapper 3 51-1236/01 Rim Assy 30-7140 Lid, Ice Bin 5 13-0005 Bushing 11-0015 Housing Socket 7 19-0077 ® 19-0078 with Soda Lever ®...
Page 19
SERIES 2400 FREE-STANDING WITH PLUG IN TOWERS (CONTINUED) ITEM PART NO. DESCRIPTION 1 42-0048 Tank Assy 2 51-0641/02 Tank Wrapper 3 51-5227/02 Rim Assy 30-7140 Lid, Ice Bin 5 13-0005 Bushing 11-0015 Housing Socket 7 19-0077 ® 19-0078 with Soda Lever ®...
LANCER ICE COOLED DISPENSER -- ACCESSORIES Illuminated Merchandiser Illuminated Marquee PN 85-2304 PN 85-2302 T & S Valve for Chilled Water Water Spigot for Ambient 19-0036 Temperature Water Kit PN 82-1597 Splash Guards Kit PN 82-2076...
Page 28
Directory of USA - Canada Offices, International Offices, and Authorized Distributors Corporate Office 6655 Lancer Blvd. • San Antonio, Texas 78219 • 210-310-7000 • 1-800-729-1500 • FAX 210-310-7250 Lancer USA Ernest F. Mariani Company Lancer Russia Manufacturing Locations 614 West 600 South...
Need help?
Do you have a question about the 2300 Series and is the answer not in the manual?