C. Remove outer nozzle and insert syrup
separator.
1. This is important to do during flow rate
check so you can determine if the
separator has been properly installed.
NOTE: Water will leak through to the syrup
chamber if not properly installed.
D. Place a ratio cup under the nozzle and
press a brand button.
1. The brand's water module will open and
pour for four seconds.
NOTE: Only water will pour during the flow
rate check.
E. Check for 10 oz of water in the ratio cup.
1. If above or below 10 oz, adjust the water
flow control (shown on previous page)
and recheck.
2.6
RATIO PROCESS
A. Remove outer nozzle and insert MVU separator if not done on previous step.
B. Prime separator by running the valve.
C. Press and fill the ratio cup to the appropriate levels.
D. Check/adjust ratio on each brand.
1. Use flow controls to adjust syrup.
13
P.N. 28-0720/05