RECOMMENDED PLUMBING, EIGHT (8) VALVE ...................44 7.13 IBD 22” COUNTER CUTOUT ...........................45 7.14 IBD 30” COUNTER CUTOUT..........................46 DISpENSER DISpOSAL..............................47 ABOUT THE LANCER IBD 4500/4600/LCD Series The IBD 4500 Series is designed using the highest quality materials and state-of-the-art technology pRE-INSTALLATION CHECKLIST pOST MIX ACCESSORIES: BIB SYSTEM: ...
IBD 4500/4600/LCD WARNINg/ADvERTENCIA/AvERTISSEMENT The dispenser is for indoor use only. This unit is not a toy. It should not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 /CARBON DIOXIDE /EL ANHíDRIDO CARBóNICO/ DIOXYDE DE CARBONE Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO2 may displace oxygen in the blood. prolonged exposure to CO2 can be harmful. personnel exposed to high concentrations of CO2 gas will experience tremors which are followed by a loss of consciousness and suffocation.
IBD 4500/4600/LCD DISpENSER INSTALLATION HIgHLIgHTS This unit has been factory sanitized per Lancer specifications. Listed below are ten critical elements which will aid in a successful installation. 1. Fill water bath until water overflows from tank overflow tube. 2. The carbonator pump motor must be disconnected from the power supply prior to connection to water supply for initial build up of ice bank.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 REgLES DE SECURITE pOUR L'NSTALLATION DU DISTRIBUTEUR DE SODAS La proprètè da cet ensamable est assurè à I'usine sulvant les spècifications èmis par Coca-Cola. Il est essentiel de respecter les 10 points suivants pour l'installation de l'appareil: 1.
IBD 4500/4600/LCD 1. INSTALLATION BEFORE gETTINg STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment. At the time of shipment, the carrier accepts responsibility for the unit. Upon receiving the unit, carefully inspect the carton for visible damage. If damage exists, have the carrier note the damage on the freight bill and file a claim with carrier.
If an icemaker is not installed, sufficient clearance must be provided, to allow for filling the ice compartment with a five gallon bucket (a minimum of 16 inches is recommended). Lancer does not recommend the use of shaved, flake, nugget, or pellet ice in the dispenser. The dispenser will only operate properly with cube ice.
Install the water regulator (Lancer PN 18-0306) included with unit as close as possible to the water carbonator pump inlet. The recommended water pressure value feeding the carbonator is a minimum of 25 PSI 172.37 kPa).
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 1.6 CONNECTINg A CARBONATOR A. If carbonator is not installed, install per manufacturer’s instructions. CAUTION/pRECAUCIóN/ATTENTION FAILURE DISCONNECT MOTOR POWER SUPPLY WILL DAMAGE CARBONATOR MOTOR, THE PUMP AND VOID THE WARRANTY. SI NO DESCONECTA LA ALIMENTACIóN ELéCTRICA DEL MOTOR PODRíAN DAñARSE LA BOMBA Y EL MOTOR...
IBD 4500/4600/LCD 1.8 INSTALLATION OF THE UNIT A. Remove Splash Plate and Top Cover. B. Remove Cover Plate at rear of unit if not a “through the counter” installation. C. Connect soda and water supply lines to 3/8 inch barb fittings at the front of the unit. Check for leaks.
2.3 Model 150 (Volumetric) Valves are preset for flows rates of 1.5 oz/sec, 2.25 oz/sec or 3.0 oz/sec based on valve part number. A hand held programmer (Lancer PN 52-1420/02) is required to set ratio on Volumetric Valves. Refer to Lancer web site (Installation Manuals 28-0027 for...
If other equipment is being cleaned, follow the guidelines established by the manufacturer for that equipment. B. Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines. The equipment must be cleaned and sanitized after installation is complete.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 CAUTION/pRECAUCIóN/ATTENTION/ FOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO NOT USE A FRESH WATER RINSE. THIS IS A NSF REqUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE SYSTEM CREATES A HEALTH HAZARD. DESPUéS DE LA ESTERILIZACIóN, ENJUAGUE CON EL PRODUCTO FINAL HASTA qUE ELIMI- NAR EL SABOR qUE qUEDA.
IBD 4500/4600/LCD 3.6 ICE BIN CLEANINg - pERFORM AT STARTUp AND MONTHLY - CONTINUED F. Remove Dispensing Wheel Shroud. WHITE WHEEL SHROUD (pELLET ICE) BLACK WHEEL SHROUD (CUBED ICE) 1. Remove the gasket which secures the 1. Remove the dispensing wheel shroud. shroud by pulling it out.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 3.7 CLEANINg AND SANITIZINg BEvERAgE COMpONENTS - BAg-IN-BOX SYSTEMS - CONTINUED D. Activate the valve and draw sanitizing solution through the line for a minimum of sixty seconds. This will ensure the line is flushed and filled with sanitizing solution. Allow the line to stand for at least thirty minutes.
G. Reverse the process to install the monitor/bracket on the unit. 3.10 MONITOR WARRANTY A. All monitor warranty claims should be processed through Lancer Corporation. Do not send claims directly to Dell. Monitor troubleshooting guide can be found on the Dell supplied CD.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 4. TROUBLESHOOTINg TROUBLE CAUSE REMEDY 4.1 No product when A. Malfunctioning switch assembly. A. Replace switch assembly. switch is activated (switch panel is not B. No power to dispenser. lit). B. Check internal breaker and incoming power.
Page 22
IBD 4500/4600/LCD TROUBLE CAUSE REMEDY 4.7 Water in ice bin. A. Coldplate drain is obstructed. A. Remove splash plate to obtain access to drain tubes and clear accordingly. 4.8 Water leakage around nozzle. A. Damaged or improperly A. If damaged, replace. installed o-ring on nozzle.
Page 23
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 TROUBLE CAUSE REMEDY 4.13 Insufficient syrup flow. A. Insufficient CO2 pressure to A. Adjust CO2 pressure to BIB pumps BIB pumps. to 80 PSI (minimum 70 PSI). Do not exceed manufacturer’s recommendations. B. Shutoff on mounting block not B.
Page 24
IBD 4500/4600/LCD TROUBLE CAUSE REMEDY 4.16 Valve will not shut off. A. Debris in solenoid seat. A. Activate valve a few times to free debris. Remove the solenoid coil and plunger. Clean out any foreign material. B. Solenoid plunger sticking. B.
Page 25
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 TROUBLE CAUSE REMEDY 4.20 Circuit breaker tripping. A. Valve wire harness shorted A. Detect short by disconnecting valve to itself or faucet plate. harnesses from switch panel (4 25-pin harnesses and 4 9-pin harnesses). Restore power. If breaker does not trip, find and replace shorted harness.
IBD 4500/4600/LCD TROUBLE CAUSE REMEDY 4.24 BIB pump fails to restart A. BIB connector not on tightly. A. Tighten BIB connector. after bag replacement. B. BIB connector is stopped up. B. Clean out or replace BIB connector. C. Kinks in syrup line. C.
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 5. LIgHT EMITTINg DIODES (LEDS) - CONTINUED 5.5 LED D7 - Light flashes when there is no ice between the sensors in the ice bin. If the bin is empty and the light is not flashing, check all wiring harnesses. 5.6 LED D8 - Light is on when the solenoid is activated.
IBD 4500/4600/LCD 7. ILLUSTRATIONS AND pARTS LISTINgS DECALS AND LABELS 2, 3, 4...
Page 29
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 DECALS AND LABELS (CONTINUED) Item part No. Description 85-4526H-100 IBD22H, Series 4500, 115V/60Hz, 6 LEV ® 85-4548H-100 IBD30H, Series 4500, 115V/60Hz, 8 LEV ® 85-4536H-100 IBD22H, Series 4500, 230V/50-60Hz, 6 LEV ® 85-4558H-100 IBD30H, Series 4500, 230V/50-60Hz, 8 LEV ®...
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 FINAL ASSEMBLY, pOST-MIX IBD AND ICE DISpENSER (CONTINUED) Item part No. Description 85-4526H IBD22H, Series 4500, 115V/60Hz,6 Valve 85-4548H IBD30H, Series 4500, 115V/60Hz,8 Valve 85-4536H IBD22H, Series 4500, 230V/50-60Hz,6 Valve 85-4558H IBD30H, Series 4500, 230V/50-60Hz,8 Valve 85-4541H IBD30H, Series 4500, 115V/60Hz,10 Valve 05-1309/02...
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 ELECTRICAL BOX AND gEAR MOTOR SUB-ASSEMBLY, pOST-MIX, IBD Item part No. Description Item part No. Description 02-0155 O-Ring, 2-015 85-4526H IBD22H, Series 4500, 52-2353 Body Assy, Detector, Sensor 115V/60Hz, 6 Valve 52-2352 Body Assy, Emitter, Sensor 85-4548H IBD30H, Series 4500, 30-8468...
IBD 4500/4600/LCD pELLET ICE DISpENSER SUB-ASSEMBLY, IBD30, CONvERSION KIT, pN 82-3633/01 NOTE: This Conversion Kit is compatible for IBDs with Serial Numbers 854545H0418M03 and above Retrofits for the 30” IBD must include PN 23-1363 (Item 5). ITEM pART NO DESCRIpTION Grommet, Rubber, 02-0577 G3002 Retainer, Pin, Agitator,...
OPERATIONS AND SERVICE MANUAL PN 28-0255/11 8. DISpENSER DISpOSAL To prevent possible harm to the environment from improper disposal, recycle the unit by locating an authorized recycle outlet or contact the retailer where the product was pur- chased. Comply with local regulations regarding disposal of the refrigerant and insulation.
Page 48
IBD 4500/4600/LCD LANCER To order parts, call Customer Service: 800-729-1500 Warranty/Technical Support: 800-729-1550 Email: custserv@lancercorp.com www.lancercorp.com...