Flow Rate Check - lancer 2308 Series Installation And Service Manual

Cold carb ice cooled dispenser
Hide thumbs Also See for 2308 Series:
Table of Contents

Advertisement

2.5

FLOW RATE CHECK

The Dispenser's water flow rate can be checked/calibrated using the on board computer as a
timer. To check/adjust flow rate:
A. Remove splashguard and module cover to expose flow controls and solenoids.
1. All active brands should have their shutoffs in the open position as illustrated below.
CW = Carbonated Water (sparkling)
PW = Plain Water (still)
B. Press the A and B buttons at the same
time for five seconds.
1. The Pour/Cancel button will illuminate and
the shot LED will blink 5 times.
P.N. 28-0720/05
12