Table A- 13
ACT_1, ACT_2
ERR_1, ERR_2
PRE_1, PRE_2 *
RxD_1, RxD_2
*) In multitag operation, this LED uses a flashing interval to indicate the number of data carriers
currently within the range of the reader.
Table A- 14
Flashes
Flashes
– = Status not relevant
Other ASM operating modes are indicated by the PRE, ERR, SF, ACT and ON LEDs:
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Status LEDs for ASM 456
LEDs
ON
Lights up when there is logic voltage applied to the CM (is generated from the 24
V supply voltage.)
24 V DC
Lights up when the 24 V supply voltage is connected to the CM.
The corresponding reader is active in processing a user command.
A flashing pattern indicates the last error to occur (see section "Error messages
(Page 47)").
Indicates the presence of a tag.
Indicates live communication with the reader. May also indicate malfunctions on
the reader.
LED display for PROFIBUS diagnostics
BF
SF
On
ASM is in start-up mode.
Connection to DP Master failed.
ASM not detecting a baud rate
Bus interrupt
DP Master not functioning
On
The project data sent to the ASM by
the DP Master do not match the
configuration of the ASM.
ASM has detected the baud rate, but
is not activated by the DP Master.
ASM has not been assigned project
plans.
On
Flashe
There is a hardware defect in the
s
ASM.
Off
On
Diagnostics available
On
Off
The set PROFIBUS address is
incorrect or greater than 99.
Meaning
Cause of error
Brief description of the hardware
A.3 ASM 456
Error correction
Check the PROFIBUS DP
connection.
Check the DP Master
Check all cables on your
PROFIBUS DP network.
Check whether the connector
plugs for the PROFIBUS DP are
securely plugged into the ASM.
Check the project for the ASM
(input/output, PROFIBUS
address).
Correct GSD file being used?
Check the PROFIBUS address set
in ASM and/or in the project
software.
Check the project for the ASM
(station type).
Replace the ASM.
Evaluate the diagnostic
information.
Set the address in the range 1 to
99 and carry out new start-up.