error_BUS
Note
The following table of bus errors does not claim to be complete. If you receive any messages
that are not documented here, you will find them in "System and standard functions S7-
300/400, volume 1/2 (http://support.automation.siemens.com/WW/view/en/44240604)".
Table 5- 4
Error code
(W#16#...)
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Error variable "error_BUS" when operating via PROFIBUS/PROFINET
800A
CM is not ready (temporary message)
This message is received by a user who is not using FB 45 and is querying the
CM acyclically in very quick succession.
8x7F
Internal error on parameter x. Cannot be remedied by the user.
8x22
Area length error on reading parameter.
8x23
Area length error on writing parameter.
This error code indicates that parameter x is partially or completely outside the
operand area or the length of a bit array for an ANY parameter is not divisible by 8.
8x24
Area error on reading parameter.
8x25
Area error on writing parameter.
This error code indicates that parameter x is within an area not allowed for the
system function.
8x26
Parameter contains a time cell number which is too high.
8x27
Parameter contains a counter cell number which is too high.
8x28
Alignment error on reading parameter.
8x29
Alignment error on writing parameter.
The reference to parameter x is an operand whose bit address is not equal to 0.
8x30
The parameter is located within the write-protected global DB.
8x31
The parameter is located within the write-protected instance DB.
8x32
The parameter contains a DB number which is too high.
8x34
The parameter contains an FC number which is too high.
8x35
The parameter contains an FB number which is too high.
8x3A
The parameter contains a DB number which is not loaded.
8x3C
The parameter contains an FC number which is not loaded.
8x3E
The parameter contains an FB number which is not loaded.
8x42
An access error occurred while the system was attempting to read a parameter from
the I/O area of the inputs.
8x43
An access error occurred while the system was attempting to write a parameter to
the I/O area of the outputs.
8x44
Error on nth (n > 1) read access after an error occurred.
8x45
Error on nth (n > 1) write access after an error occurred.
8090
Specified logical base address is invalid: No assignment in SDB1/SDB2x exists, or it
is not a base address.
8092
A type other than BYTE has been specified in an ANY reference.