Examples/applications
6.7 The UDTs of FB 45 / FC 45
UDT 121: Result of reader diagnostics I
Table 6- 5
UDT 121 "MOBY SLG-Stat Diag 1"
Address
Name
0.0
+0.0
status_info
+1.0
number_functions
+2.0
function_01_01
+3.0
function_01_02
+4.0
function_01_03
.
.
.
.
.
.
=234.0
*) An area of 7 bytes each is reserved for 33 commands.
UDT 131: Result of reader diagnostics II
Table 6- 6
UDT 131 "MOBY SLG-Stat Diag 2"
Address
Name
0.0
+0.0
status_info
+1.0
number_errors
+2.0
error_number
*1.0
=238.0
UDT 141: Result of reader diagnostics III
Table 6- 7
UDT 141 "MOBY SLG-Stat Diag 3"
Address
Name
0.0
+0.0
status_info
+1.0
number_MDS
+2.0
UID
*4.0
=98.0
76
Type
STRUCT
BYTE
BYTE
BYTE
BYTE
BYTE
END_STRUCT
Type
STRUCT
BYTE
BYTE
ARRAY [1...235]
BYTE
END_STRUCT
Type
STRUCT
BYTE
BYTE
ARRAY [1...24]
DWORD
END_STRUCT
Comment
Reader status mode
Range: 1...33
*
*
*
Comment
Reader status mode
Range: 1...235
Error that occurred on the reader
Comment
Reader status mode
Range: 1...24
identified UID (tag number)
FB 45 for MOBY U, MOBY D, RF200, RF300