Siemens SIMATIC Ident Function Manual page 78

For moby u, moby d, rf200, rf300
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Examples/applications
6.7 The UDTs of FB 45 / FC 45
Address
Name
+12.0
reserved1
*1.0
=18.0
UDT 271: Result of MDS status (mode 2, RF300)
Table 6- 10
UDT 271: "MDS status (mode 2, RF300)"
Address
Name
0.0
+0.0
reserved0
+1.0
status_info
+2.0
UID
*0.0
+0.0
Byte_1_4
+4.0
Byte_5_8
+8.0
+10.0
LFD
+11.0
FZP
+12.0
FZA
+13.0
ANWZ
+14.0
reserved1
*0.0
=18.0
UDT 281: Result of read/write status (mode 6, RF300)
Table 6- 11
UDT 281 "Reader status (mode 6, RF300)"
Address
Name
0.0
+0.0
status_info
+1.0
FZP
+2.0
ABZ
+3.0
CFZ
+4.0
SFZ
+5.0
CRCFZ
+6.0
BSTAT
+7.0
ASMFZ
+8.0
res.
to
+26.0
=28.0
78
Type
Comment
ARRAY[1...6]
BYTE
END_STRUCT
Type
Comment
STRUCT
BYTE
BYTE
Tag status mode
ARRAY[1...1]
STRUCT
DWORD
Tag number (unique identifier)
DWORD
END_STRUCT
BYTE
Power flux density: Relationship between the
limit value and measured value
BYTE
Error counter, passive (errors during idle
time)
BYTE
Error counter, active (errors during
communication)
BYTE
Presence counter
ARRAY[1...3]
BYTE
END_STRUCT
Type
Comment
STRUCT
BYTE
Reader status mode
BYTE
Error counter, passive (errors during idle time)
BYTE
Abort counter
BYTE
Code error counter
BYTE
Signature error counter
BYTE
CRC error counter
BYTE
Current command status
BYTE
Interface error counter for CM
BYTE
Reserved
END_STRUCT
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fb 45

Table of Contents