Brief description of the hardware
A.1 RF170C
After start-up or updating the firmware, the LEDs SF, PRE, ERR and ACT indicate the
operating status or faults of the RF170C:
SF
PRE_1
ERR_1
Off
Off
Off
On
Off
On
On
Off
Off
On
On
On
On
Off
On
On
On
On
On
Off
On
On
On
Off
On
Off
On
Off
1 x flash
every 3 s
n x flash
every 3 s
Flashing
– = not relevant
* If this error recurs, the module is defective and must be replaced.
Interfaces of the RF170C
Table A- 4
X1, X2: Connector for reader
Pre-assembled reader connecting cables are available for the RF170C.
The appropriate cable and M12 connectors are available for users who want to assemble
their own SIMATIC RFID cables.
84
ACT_1
PRE_2
ERR_2
On
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
On
Off
On
On
Off
On
On
On
On
On
On
On
On
On
Off
Off
Off
1 x flash
every 3 s
m x flash
every 3 s
Rapid
Flashing
flashing
Pin assignment of the interfaces of the RF170C
ACT_2
Description
Off
Start-up active
Off
Checksum error at start-up *
Off
Firmware invalid *
On
LED test for approximately 4 seconds;
otherwise firmware fault *
On
Checksum error at start-up *
On
Checksum error of the firmware *
On
External RAM defective *
On
ESSA3 defective *
On
ID error firmware *
Off
RF170C successfully started up, waiting
for reset command
The number of flashes (n, m) indicates the
last reported error on a given channel.
Rapid
Firmware update; alternate flashing of the
flashing
error LEDs at approximately 1 Hz
Pin
1
2
3
4
5
6
7
8
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Signal
+24 V
–RxD
0 V
RxD
TxD
–TxD
free
PE / shield